[HTML][HTML] Clinical significance of the neural response telemetric thresholds in Mandarin-speaking cochlear implant patients
… within the cochlea between surgery and postoperative evaluation. Postoperatively, the NRT
… In contrast, other studies have found no positive or negative correlation between insertion …
… In contrast, other studies have found no positive or negative correlation between insertion …
[HTML][HTML] Intraoperative Measurement of Insertion Speed in Cochlear Implant Surgery: A Preliminary Experience with Cochlear SmartNav
S Concheri, D Brotto, M Ariano, A Daloiso… - Audiology …, 2024 - mdpi.com
… No correlation was found between IS and the NRT ratio (p = 0.51), pure-tone audiometry (…
recognition score (p = 0.231) at last evaluation. Conclusions: The estimated IS reported by …
recognition score (p = 0.231) at last evaluation. Conclusions: The estimated IS reported by …
Effect of the vertical facial canal to round window distance concerning neural response telemetry during cochlear implantation in children
J Singh, RK Singh, SK Mishra, S Jha - International Journal of Pediatric …, 2022 - Elsevier
… to measure and evaluate the T-NRT current level… relationship between the round window
to vertical facial canal distance and the NRT ratio, electrode insertion angle, and, after cochlear …
to vertical facial canal distance and the NRT ratio, electrode insertion angle, and, after cochlear …
Misplaced Cochlear Implant Electrodes Outside the Cochlea: A Literature Review and Presentation of Radiological and Electrophysiological Findings
LL Cheung, J Kong, PY Chu, H Sanli… - Otology & …, 2022 - journals.lww.com
… are reported from our institution with a rate of 0.28%. A further … during cochlear implantation
with full array insertion include … However, we note that NRT was not conducted in four out of …
with full array insertion include … However, we note that NRT was not conducted in four out of …
[PDF][PDF] Elektrophysiologische Effekte der slim straight intracochlearen Elektrodenposition
JFO Córdova - d-nb.info
… threshold ratio is the relative variation of the distance between … during cochlear implant
electrode insertion in relation to the … insertion: a radiologic and pitch scaling assessment of two …
electrode insertion in relation to the … insertion: a radiologic and pitch scaling assessment of two …
[HTML][HTML] Comparison of Perioperative Electrophysiological Measurements and Postoperative Results in Cochlear Implantation with a Slim Straight Electrode
T Gabrovec, J Dragar, D Guzelj, PP Bržan, J Rebol - Applied Sciences, 2023 - mdpi.com
… [10] did not prove the correlation between a greater insertion angle and a smaller NRT ratio.
… average, however, frequency-specific analysis revealed a weak but significant relationship …
… average, however, frequency-specific analysis revealed a weak but significant relationship …
Correlation between auditory response telemetry (ART) and computerized tomography measurements in detection of cochlear implant electrode position
SH Saeed, AA Abdelwehab… - Egyptian Journal of …, 2023 - ejnso.journals.ekb.eg
… Full insertion of the CI electrode array and insertion in scala tympani … does NRT threshold,
by assessment of the link between electrode array distance and modiolus using CT and NRT …
by assessment of the link between electrode array distance and modiolus using CT and NRT …
Potential insertion complications with cochlear implant electrodes
A Ishiyama, F Risi, P Boyd - Cochlear Implants International, 2020 - Taylor & Francis
… cochlear anatomy and patency are anticipated to be normal. Figure 1 illustrates the main
types of complication considered in this review. … Many studies have also reported a high rate of …
types of complication considered in this review. … Many studies have also reported a high rate of …
Effect of inner ear malformations on intraoperative ECAP thresholds and postoperative auditory performance
JS Kim, SH Hong, IJ Moon - Laryngoscope Investigative …, 2022 - Wiley Online Library
… This study evaluated the use of intraoperative ECAP … after electrode insertion. Neural response
telemetry (… default NRT recording parameters were used; (1) a stimulation rate of 250 Hz, (…
telemetry (… default NRT recording parameters were used; (1) a stimulation rate of 250 Hz, (…
Comparative study of two different perimodiolar and a straight cochlear implant electrode array: surgical and audiological outcomes
O Garaycochea, R Manrique-Huarte, C Lazaro… - European Archives of …, 2020 - Springer
… ) with an anatomically normal cochlea, a complete insertion of the … score for speech perception
assessment were better with … neural response telemetry-ratio (NRT-ratio) to determine the …