Use of intraoperative CT scanning for quality control assessment of cochlear implant electrode array placement
RF Labadie, AD Schefano, JT Holder… - Acta oto …, 2020 - Taylor & Francis
… Background: Imaging of cochlear implant (CI) electrode … post-operative computerized
tomography (CT) if concern exists … Perhaps more clinically applicable is the use of flat plate …
tomography (CT) if concern exists … Perhaps more clinically applicable is the use of flat plate …
[HTML][HTML] Evaluation after cochlear implant surgery: Correlation of clinical outcome and imaging findings using flat-detector CT
A Stock, V Bozzato, SP Kloska, A Bozzato… - Clinical …, 2021 - Springer
… imaging, which is routinely performed on CI patients in our department, to determine the exact
electrode positioning after cochlear implant … reliability of this imaging technique, which is …
electrode positioning after cochlear implant … reliability of this imaging technique, which is …
Cone-beam CT versus multidetector CT in postoperative cochlear implant imaging: evaluation of image quality and radiation dose
RA Helal, R Jacob, MA Elshinnawy… - American Journal …, 2021 - Am Soc Neuroradiology
… As in most cases, the use of MR imaging after a CI must be limited, so the electrode position
… the use of flat panel CT in the clinical assessment of patients with cochlear implants. AJNR …
… the use of flat panel CT in the clinical assessment of patients with cochlear implants. AJNR …
Fluoroscopy guided electrode-array insertion for cochlear implantation with straight electrode-arrays: a valuable tool in most cases
C Perazzini, M Puechmaille, N Saroul… - European Archives of …, 2021 - Springer
… Fifty-three cochlear implantation procedures were achieved under … electrodes out of the
cochlea in revision surgery. Final 3D cone beam CT scan double-checked the EA position in all …
cochlea in revision surgery. Final 3D cone beam CT scan double-checked the EA position in all …
[HTML][HTML] … secondary reconstructions of flat-panel volume computed tomography (fpVCT) and otological planning software for anatomically based cochlear implantation
FT Müller-Graff, L Ilgen, P Schendzielorz… - European Archives of …, 2022 - Springer
… Furthermore, for the purpose of evaluating the accuracy of the determination of electrode
contact positions in the different imaging modalities, distances between every single …
contact positions in the different imaging modalities, distances between every single …
[HTML][HTML] Evaluation of artifacts of cochlear implant electrodes in cone beam computed tomography
… (CBCT) offers a valid alternative to conventional Computed Tomography (CT). A … imaging
of CIs is of great importance. Whether the visualization of Cochlear Implant (CI) electrodes in …
of CIs is of great importance. Whether the visualization of Cochlear Implant (CI) electrodes in …
Electrophysiological detection of electrode fold-over in perimodiolar cochlear implant electrode arrays: a multi-center study case series
P Mittmann, G Lauer, A Ernst, S Mutze… - European Archives of …, 2020 - Springer
… who had all undergone a mandatory postoperative HR-CT or DVT scan. … Best, Netherlands)
with a flat-panel detector [14]. At UE, flat-panel CT examinations were performed on a Philips …
with a flat-panel detector [14]. At UE, flat-panel CT examinations were performed on a Philips …
Merged volume rendered flat-panel computed tomography for postoperative cochlear implant assessment
F Eisenhut, S Lang, L Taha, A Doerfler, H Iro… - Clinical …, 2020 - Springer
… Case 2: 33-year-old patient with cochlear implant tip fold over of the last 4 electrodes. … FD-CT
is regarded as the preferred imaging modality for postoperative control of cochlear implants …
is regarded as the preferred imaging modality for postoperative control of cochlear implants …
Assessment of frequency-place mismatch by flat-panel CT and correlation with cochlear implant performance
D Zanetti, G Conte, F Di Berardino, FL Russo… - Otology & …, 2021 - journals.lww.com
… between electrode place and assigned frequency on Computed tomography (CT) images
has … Multiplanar reconstruction (MPR) images of a left-sided cochlear implant. MPR axes are …
has … Multiplanar reconstruction (MPR) images of a left-sided cochlear implant. MPR axes are …
On the intracochlear location of straight electrode arrays after cochlear implantation: How lateral are lateral wall electrodes?
R Salcher, A Boruchov, M Timm, M Steffens… - Otology & …, 2021 - journals.lww.com
… Imaging evaluation of electrode placement and effect on electrode discrimination on different
cochlear implant … Intracochlear position of cochlear implants determined using CT scanning …
cochlear implant … Intracochlear position of cochlear implants determined using CT scanning …