Plasmonic optical biosensors for detecting c-reactive protein: A review

JS Seok, H Ju - Micromachines, 2020 - mdpi.com
… CRP has a pentameric structure of the five identical … , and the sandwich assay modified
with metal nanoparticles or … the surface plasmon resonance (SPR)-based C-reactive protein (…

Oriented Antibody Covalent Immobilization for Label-Free Impedimetric Detection of C-Reactive Protein via Direct and Sandwich Immunoassays

A Adesina, P Mashazi - Frontiers in Chemistry, 2021 - frontiersin.org
… for the detection of C-reactive protein (CRP). The gold electrode modified with boronic
acid–terminated … This antibody-modified surface was able to capture human CRP protein, and the …

Online regeneration of a piezoelectric and impedimetric immunosensor for the detection of C-reactive protein on the oriented antibody gold surface

A Adesina, O Adeniyi, P Mashazi - Analytical Methods, 2023 - pubs.rsc.org
… In addition, CRP is a pentameric protein with several binding sites for the antibodies, thus …
for the C-reactive protein using a screen-printed carbon electrode modified with graphene and …

Application of hybrid Au@ Ag nanostructures in fiber optic biosensor for rapid detection of C-reactive protein

NTT Phuong, NHN Thao, HKT Ta, NQM Tran, TN Bach… - Optical Materials, 2023 - Elsevier
… material for optical fiber sensor application to sensitively monitor C-reactive protein
Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance

Diagnoses based on C-reactive protein point-of-care tests

M Pohanka - Biosensors, 2022 - mdpi.com
… the common pentameric form of CRP or total CRP not distinguishing monomeric and …
resonance sensor chip was modified by protein A and albumin was used for saturating the surface

Ionic strength-sensitive and pH-insensitive interactions between C-reactive protein (CRP) and an anti-CRP antibody

Y Oka, S Ushiba, N Miyakawa, M Nishio… - Biophysics and …, 2022 - jstage.jst.go.jp
C-reactive protein (CRP) is regarded as a universal biomarker … using field-effect transistors
(FETs) [8], surface plasmon … , as many factors may modify the binding properties. Therefore, it …

Surface plasmon resonance (SPR) spectroscopy and photonic integrated circuit (PIC) biosensors: A comparative review

P Steglich, G Lecci, A Mai - Sensors, 2022 - mdpi.com
… In this case, we observe a resonance wavelength, which will be changed after a binding …
Since the level of the C-reactive protein (CRP) is a very important parameter in many cases, …

Recent advancements in receptor layer engineering for applications in SPR-based immunodiagnostics

M Drozd, S Karoń, E Malinowska - Sensors, 2021 - mdpi.com
… in the development of surface plasmon resonance-based … pentamer C-reactive protein (CRP)
and modified CRP were … compared to other immunodetection methods. Biosensors with an …

Buried-gate MWCNT FET-based nanobiosensing device for real-time detection of CRP

A Firoozbakhtian, AH Rezayan, H Hajghassem… - ACS …, 2022 - ACS Publications
C-reactive protein (CRP), an acute-phase protein synthesized in the liver in response to
inflammation, is one of the biomarkers used for the detection of several diseases. Sepsis and …

Biosensors; noninvasive method in detection of C-reactive protein (CRP)

HH Khanmiri, F Yazdanfar, A Mobed… - Biomedical …, 2023 - Springer
pentameric pCRP is frequently used as a prognostic indicator of a patient's risk of emerging
Cardiovascular disease (CVD). Structural modificationsSurface plasmon resonance (SPR) …