Efficient embedded sleep wake classification for open-source actigraphy
… as an acceptably accurate estimate of sleep patterns in normal … work come from relatively
long monitoring windows (about 14 … alignment between actigraphy and polysomnography, we …
long monitoring windows (about 14 … alignment between actigraphy and polysomnography, we …
Actigraphy: Metrics reveal it is not a valid tool for determining sleep in neonates
M Derbin, L McKenna, D Chin, B Coffman… - Journal of sleep …, 2022 - Wiley Online Library
… in preterm infants, using polysomnography (PSG) as the “gold standard”. A total of 10 neonates
(mean [SD] 35.8 [1.2] … The actigraph is typically placed on the subject’s ankle or wrist and …
(mean [SD] 35.8 [1.2] … The actigraph is typically placed on the subject’s ankle or wrist and …
Optimizing actigraphic estimates of polysomnographic sleep features in insomnia disorder
BHW Te Lindert, WP van der Meijden, R Wassing… - Sleep, 2020 - academic.oup.com
… the accuracy of actigraphic estimates of sleep onset or nocturnal … is the continuous recording
of movement, usually of the wrist. … to all measurements to calculate all-night sleep feature …
of movement, usually of the wrist. … to all measurements to calculate all-night sleep feature …
The accuracy of simple, feasible alternatives to polysomnography for assessing sleep in intensive care: An observational study
… sleep monitoring techniques such as actigraphy (ACTG), behavioural assessments, and
patient surveys are comparable with polysomnography (PSG) in accurately reporting sleep …
patient surveys are comparable with polysomnography (PSG) in accurately reporting sleep …
Diagnostic value of actigraphy in hypersomnolence disorders
EW Torstensen, L Pickering, BR Kornum, B Wanscher… - Sleep Medicine, 2021 - Elsevier
… of actigraphy to quantify sleep continuity measures in comparison with polysomnography
in … The accuracy of actigraphy in the diagnosis of NT1 is not clarified, although our findings …
in … The accuracy of actigraphy in the diagnosis of NT1 is not clarified, although our findings …
Validation of sleep measurement in a multisensor consumer grade wearable device in healthy young adults
… than traditional polysomnography (PSG) and actigraphy. Additionally, … , Inc.), worn on the
nondominant wrist throughout the … Notably, accuracy, sensitivity, and specificity values are likely …
nondominant wrist throughout the … Notably, accuracy, sensitivity, and specificity values are likely …
Validation of the Munich Actimetry Sleep Detection Algorithm for estimating sleep–wake patterns from activity recordings
AS Loock, A Khan Sullivan, C Reis… - Journal of sleep …, 2021 - Wiley Online Library
… differently from polysomnography in other sleep parameters. These … In turn, actigraphy or
actimetry (as we prefer to call it) … Sensitivity, specificity, predictive values and overall accuracy …
actimetry (as we prefer to call it) … Sensitivity, specificity, predictive values and overall accuracy …
Validation of an automated sleep detection algorithm using data from multiple accelerometer brands
T Plekhanova, AV Rowlands, MJ Davies… - Journal of Sleep …, 2023 - Wiley Online Library
… each wrist with concurrent laboratory-based polysomnography (… GENEActiv and ActiGraph
accelerometers, worn on either wrist, … Additionally, sensitivity, specificity, and accuracy of the …
accelerometers, worn on either wrist, … Additionally, sensitivity, specificity, and accuracy of the …
Validation of photoplethysmography-and acceleration-based sleep staging in a community sample: comparison with polysomnography and Actiwatch
PK Liu, N Ting, HC Chiu, YC Lin, YT Liu… - … of Clinical Sleep …, 2023 - jcsm.aasm.org
… Although wrist-worn consumer wearables are widely used for home sleep monitoring, few
have … We should consider the impact of dominant and nondominant wrists on the accuracy of …
have … We should consider the impact of dominant and nondominant wrists on the accuracy of …
A comparison of agreement between actigraphy and polysomnography for assessing sleep during posttraumatic amnesia
B Fedele, D McKenzie, G Williams, R Giles… - … of Clinical Sleep …, 2022 - jcsm.aasm.org
… actigraphy for determining (sleep/wake time, sleep efficiency, … This is the first study to evaluate
the accuracy of actigraphy … employed actigraphy (an accelerometer-based wrist Actigraph …
the accuracy of actigraphy … employed actigraphy (an accelerometer-based wrist Actigraph …