[HTML][HTML] Standardizing radiation exposure during cardiac catheterization in children with congenital heart disease: data from a multicenter Brazilian registry

JL Manica, VO Duarte, M Ribeiro, A Hartley… - Arquivos brasileiros de …, 2020 - SciELO Brasil
… strategies to reduce radiation exposure in this … Quantification of temporal, procedural, and
hardware-related factors influencing radiation exposure during pediatric cardiac catheterization

[HTML][HTML] Radiation dose reduction in congenital heart disease patients during cardiac catheterization by a novel protocol

S Gokalp, IC Tanidir, E Ozturk, Y Ergul… - … Archives of Pediatrics, 2021 - ncbi.nlm.nih.gov
… The radiation dose was quantified as air kerma dose (mGy) and … possible to reduce radiation
exposure by lowering the frame rate in children undergoing cardiac catheterization without …

Cardiac catheterization real-time dynamic radiation dose measurement to estimate lifetime attributable risk of cancer

CY Tu, CJ Lin, BH Yang, J Wu, TH Wu - Plos one, 2020 - journals.plos.org
… Optimizing the fluoroscopy or cine acquisition dose rate to reduce staff radiation dose
and long-term risk is much more efficient. Ishibashi et al. [56] reported the fluoroscopy …

Radiation dose reduction for 3D angiography images in pediatric and congenital cardiology

KA Fetterly, A Ferrero, BR Lewis… - Catheterization and …, 2021 - Wiley Online Library
… -dose 3DA to guide cardiovascular interventional procedures. To this end, prospective study
of the potential to substantially reduce 3DA radiation dose during pediatric … to measuring

Catheter strategy to ease the procedure and reduce radiation exposure when requiring neck access

R Kubicki, J Hummel, R Höhn, K Müller, B Stiller… - … heart, 2020 - openheart.bmj.com
radiation exposure for staff, using different phantoms (paediatric and adult) to quantify the
occupational dose … defined measuring points inside the cardiac catheterisation laboratory in …

Simple evaluation method for radiation dose monitoring using fluoroscopic dose rate in cardiac catheterization for pediatric congenital heart disease

Y Oribe, H Yabe, H Tanaka, Y Matsuura… - … Society of Pediatric …, 2021 - jstage.jst.go.jp
Calculating this statistic is easy, and future database research may facilitate inter-center …
Thus, it is vital that we work to reduce radiation doses associated with cardiac catheterization

Pregnancy in the cardiac catheterization laboratory: A safe and feasible endeavor

AE Cheney, LL Vincent, JM McCabe… - … : Cardiovascular …, 2021 - Am Heart Assoc
radiation exposure during pregnancy with an emphasis on radiation quantification, the impact
of exposure … attentive to universal strategies to reduce radiation exposure based on the as …

Pediatric/congenital cardiac catheterization quality: an analysis of existing metrics

ML O'Byrne, J Huang, I Asztalos, CL Smith… - Cardiovascular …, 2020 - jacc.org
… failure to rescue along with radiation exposure) or as a structure (… in measuring and reporting
quality performance of pediatric/… by reducing costs. Relative to their prevalence, congenital …

Diagnostic reference levels, deterministic and stochastic risks in pediatric interventional cardiology procedures

C Rizk, G Fares, F Vanhavere, Z Saliba, J Farah - Health Physics, 2020 - journals.lww.com
… Of the 373 patients, 103 underwent cardiac catheterization procedures for diagnostic …
Therefore, effort should be made to minimize the radiation exposure during pediatric DP and ASD …

Comprehensive strategies to minimize radiation exposure during Interventional electrophysiology procedures: state-of-the-art review

M Desai, O Kahaly, A Aslam, J Saifa-Bonsu… - Expert Review of …, 2020 - Taylor & Francis
… been conducted to quantify average radiation exposure for … However, many of these studies
were conducted in children (… to reduce procedure times, increase the precision of catheter