Retentive force variations in three polyamide and a polyetheretherketone denture attachments for implant-supported overdentures: an in vitro study

M Βei, SN Kamalakidis, AL Pissiotis… - The Journal of Prosthetic …, 2023 - Elsevier
… The mean retention loss for Ball attachment was 15.3% after … the evaluated overdenture
attachments during the period of … implant design, with vertical axial loading and 37 C tap water …

Attachment-Retained Overdentures

Y Ozkan, R Gozneli - … and After Edentulism: Tooth Supported Overdentures, 2023 - Springer
overdenture (TSO) attachments are typically placed directly … for allowing maintenance of the
contact during vertical loading. … This can lead to metal fatigue and eventual attachment failure…

One-time definitive attachment connection versus healing abutment placement for an implant-retained mandibular overdenture: Peri-implant metabolic activity

AM Ibrahim, M Elgamal, NA Ragheb - The Journal of Prosthetic Dentistry, 2024 - Elsevier
… placed with a delayed implant loading protocol is still unclear.26, … effectiveness of directly
placing the definitive attachment at the … period compared with the 7-day period for both groups. …

The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems

S Monteiro, P Barreiros, J Mendes, C Aroso, AS Silva… - Biomedicines, 2023 - mdpi.com
… of conventional complete denture therapy is directly affected by … , since each has its own
mechanical properties and loadperiod of 12 months followed by simulated cycles of function. …

Microstrain analysis of implants retained complete mandibular overdenture by using two different attachments (an in vitro study)

MAA Goher, ZA El-Shorbagy, ZMA Aal - Tanta Dental Journal, 2021 - journals.lww.com
… Bar attachment provides a direct mechanical attachment … and oblique load situation the use
of ERA attachment reduced … gold ERA overdentures abutment is smaller than any attachment

Retention and wear of nylon matrix component in implantsupported overdentures based on insertion technique: A clinical trial.

P Amini, S Abyari, P Pourmoshrefi… - Journal of Dental …, 2023 - search.ebscohost.com
… tensile load directly below the overdenture border until the … Studies on the required load
for overdenture retention have … the overdentures by themselves over a relatively long period. …

Effect of various retentive element materials on retention of mandibular implant-retained overdentures

A Chindarungruangrat, T Eiampongpaiboon… - Molecules, 2022 - mdpi.com
… in acrylic blocks using direct attachment pick-up techniques. Metal … After the simulated
period of 12 months, the final retentive forces (… Many oral factors, including masticatory loading, …

Comparison of Three Types of Stud Attachments on Retention and Strain Energy in the Mandibular Implant-Supported Overdentures

G Esfahanizadeh, S Mohammadi-Asl… - European Journal of …, 2020 - ejdent.org
period, replacement of prosthetic components, force distribution … It has been observed that
there is a direct relationship … a decrease in retention from the primary test to the last loadings. …

Retention loss and wear assessment of three attachment systems for implant retained-mandibular overdentures: An in vitro study

R Wakam, S Ramalingam, KB Mawussi, C Gorin… - Journal of the …, 2024 - Elsevier
… /CAM resin blocks and cyclically loaded with 19.6 N along the … axis, corresponding to a
simulated fatigue period of 5.5 years … This retention loss was directly attributable to the wear of the …

[PDF][PDF] FIBER-REINFORCED IMPLANT-RETAINED OVERDENTURES

MFEM Gibreel - utupub.fi
… at the attachment area of implantretained overdentures (IODs) … on the load-bearing
capacity of simulated locator-retained … on the fatigue resistance of simulated single locator-retained