Energy expenditure estimation of tabata by combining acceleration and heart rate

Y Yan, Q Chen - Frontiers in Public Health, 2022 - frontiersin.org
… powerful energy expenditure prediction approach is to use ACC and HR simultaneously. …
which is the basic principle behind the combination of these techniques (16). In addition, the …

Prediction of energy expenditure during activities of daily living by a wearable set of inertial sensors

M Hedegaard, A Anvari-Moghaddam… - Medical engineering & …, 2020 - Elsevier
methods for monitoring activities of daily living (ADL) to predict total energy expenditure (TEE)
is … Hence, this study aims to estimate TEE during ADL by using gender, heart rate, and an …

Robust heart rate monitoring by a single wrist-worn accelerometer based on signal decomposition

C Zhao, W Zeng, D Hu, H Liu - IEEE Sensors Journal, 2021 - ieeexplore.ieee.org
… , “Estimating energy expenditure with multiple models using different wearable sensors,” …
Zhang et al., “Technology development for simultaneous wearable monitoring of cerebral …

Simple prediction of metabolic equivalents of daily activities using heart rate monitor without calibration of individuals

Y Caballero, TJ Ando, S Nakae, C Usui… - International journal of …, 2020 - mdpi.com
… of total energy expenditure (EE), far more than exercise [3,4]. Therefore, an accurate measure
of daily … an accelerometer and an HR sensor (simultaneous use of HR and motion sensor

[HTML][HTML] Estimating Physical Activity and Sleep using the Combination of Movement and Heart Rate: A Systematic Review and Meta-Analysis

JW WHITE III, CD Pfledderer, P Kinard… - … Journal of Exercise …, 2023 - ncbi.nlm.nih.gov
energy expenditure estimates from wrist- or arm-worn devices during different activity types
in adults reported that the accuracy of energy expenditure estimatesmethods to assess

RGB and near-infrared light reflectance/transmittance photoplethysmography for measuring heart rate during motion

K Matsumura, S Toda, Y Kato - IEEE Access, 2020 - ieeexplore.ieee.org
… A technique to reduce the effects of motion artifacts during … was developed to enable
simultaneous measurements under … This study aimed to determine the extent of motion artifacts in …

Validity of Wrist-Worn photoplethysmography devices to measure heart rate: a systematic review and meta-analysis

Y Zhang, RG Weaver, B Armstrong… - Journal of Sports …, 2020 - Taylor & Francis
… , can dramatically improve estimates of energy expenditure and sleep. Advancements in …
Simultaneous heart rate-motion sensor technique to estimate energy expenditure. Medicine …

An adaptive filter based motion artifact cancellation technique using multi-wavelength PPG for accurate HR estimation

P Park, W Lee, SH Cho - IEEE Transactions on Biomedical …, 2023 - ieeexplore.ieee.org
… To accurately estimate the power and area of the proposed … Its size is 0.254 mm2 and its
power consumption is 30 nW. … and finger PPG are measured simultaneously for 30 seconds. …

Reducing Motion Artifacts of Pulse Intervals from Photoplethysmogram of a Commercial Wristband for Heart Rate Variability Analysis

H Wang, H Jimison, M Pavel - 2021 43rd Annual International …, 2021 - ieeexplore.ieee.org
… to the simultaneously measured heart rate using ECG. … Various methods and techniques
have been developed to address … estimation of average heart rate [4], instead of instantaneous …

Estimation of energy consumed by middle-aged recreational marathoners during a marathon using accelerometry-based devices

C Hernando, C Hernando, I Martinez-Navarro… - Scientific Reports, 2020 - nature.com
… For all individuals, we estimated the energy cost of running a marathon, presenting the …
were observed between the speed- and accelerometry-based methods. These differences lie in …