Clinical Experience with a New Software‐Based Antitachycardia Pacemaker for Recurrent Supraventricular and Ventricular Tachycardias

M Fromer, H Gloor, T Kus… - Pacing and Clinical …, 1990 - Wiley Online Library
The Intermedics Intertach 262–12 tachycardia reversion pulse generator was implanted in
14 patients (six male, eight female, mean age at implantation 45±16 years) with recurrent …

Safety of antitachycardia pacing in patients with implantable cardioverter defibrillators and severely depressed left ventricular function

A Heisel, J NEUZNER, E Himmrich… - Pacing and Clinical …, 1995 - Wiley Online Library
The purpose of this study was to investigate the efficacy and safety of antitachycardia pacing
(ATP) in third‐generation implantable Cardioverter defibrillators (ICDs) for terminating …

Randomized, prospective comparison of four burst pacing algorithms for spontaneous ventricular tachycardia

R Peinado, J Almendral, T Rius, A Moya… - American Journal of …, 1998 - ajconline.org
Several studies have analyzed the efficacy of a variety of antitachycardia pacing (ATP)
modalities in induced and spontaneous monomorphic ventricular tachycardia (MVT). 1–18 …

Multiple attempts of antitachycardia pacing are useful in implantable cardioverter-defibrillators

A Schaumann, A Poppinga, C Neufert… - Journal of the American …, 1998 - elibrary.ru
We evaluated to what extent multiple attempts of antitachycardia pacing (ATP) are useful in
patients with implantable cardioverter-defibrillators (ICD). Devices of 38 patients with …

Efficacy of antitachycardia pacing in patients presenting with cardiac arrest

RL Mitra, HH Hsia, BG Hook, DJ Callans… - Pacing and Clinical …, 1995 - Wiley Online Library
The efficacy of antitachycardia pacing (ATP) incorporated into implantable cardioverter
defibrillators (ICDs) was assessed in 29 consecutive survivors of cardiac arrest, not …

Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study

RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
Aims Little is known about the optimal number of antitachycardia pacing (ATP) attempts to
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …

Initial clinical experience with a new automated antitachycardia pacing algorithm: feasibility and safety in an ambulatory patient cohort

R Yee, JD Fisher, U Birgersdotter-Green… - Circulation …, 2017 - Am Heart Assoc
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD)
decreases patient shock burden but has recognized limitations. A new automated ATP …

[HTML][HTML] Successful termination of ventricular tachycardia with intrinsic anti-tachycardia pacing

I Morishima, Y Kanzaki, Y Morita, Y Tsuji - Indian Pacing and …, 2021 - Elsevier
Intrinsic anti-tachycardia pacing (iATP) is a novel automated ATP algorithm that employs
post-pacing interval (PPI) to design the next ATP sequence based on an analysis of the prior …

Long‐term antitachycardia pacing experience for supraventricular tachycardia

K den Dulk, P Brugada, JL Smeets… - Pacing and Clinical …, 1990 - Wiley Online Library
A pacemaker was used to control drug‐resistant reentrant Supraventricular tachycardia
(SVT) in 40 patients. An antitachycardia pacemaker was impJanted in 37 for SVT; in one for …

Anti‐tachycardia pacing for non‐fast and fast ventricular tachycardias in individual Japanese patients: from Nippon‐storm study

M Chinushi, O Saitoh, H Furushima… - Journal of …, 2021 - Wiley Online Library
Background Anti‐tachycardia pacing (ATP) delivered from an implantable device is a useful
tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for those patients …