Comparison of fixed burst versus decremental burst pacing for termination of ventricular tachycardia

H Calkins, R EL‐ATASSI, S Kalbfleisch… - Pacing and Clinical …, 1993 - Wiley Online Library
The objective of this study was to compare prospectively the efficacy of fixed burst pacing
with that of decremental hurst pacing in terminating VT. Forty‐four patients with inducible …

Patient-activated transvenous cardiac stimulation for the treatment of supraventricular and ventricular tachycardia

GO Hartzler, DR Holmes Jr, MJ Osborn - The American journal of cardiology, 1981 - Elsevier
Recurrent, drug-refractory sustained tachycardias present a difficult management problem.
After invasive electrophysiologic study and extensive antiarrhythmic drug testing, a …

Long‐Term Management of Ventricular Tachycardia by Implantable Automatic Burst Tachycardia‐Terminating Pacemakers

MD Falkoff, SS Barold, MA Goodfriend… - Pacing and Clinical …, 1986 - Wiley Online Library
This report describes the Jong‐term follow‐up of two patients who received implantable
automatic burst tachycardia‐terminating ventricular pacemakers for the treatment of drug …

'Long‐Term Results of Antitachycardia Pacing in Patients with Supraventricular Tachycardia

I Schnittger, JT Lee, J Hargis… - Pacing and Clinical …, 1989 - Wiley Online Library
Between 1979 and 1984 the Cybertach‐60,(Intermedics, Inc. Model 262–01), a
programmable, automatic antitachycardia pacemaker was implanted in 11 patients who had …

Safety and Efficacy of Pacing for Ventricular Tachycardia: Sécurité et Efficacité de la Stimulation dans les Tachycardies Ventriculaires

LK Holley, M Cooper, JB Uther… - Pacing and Clinical …, 1986 - Wiley Online Library
This study was undertaken to determine the safety and efficacy of three different pacing
modalities on the termination of ventricular tachyarrhythmias. Thirty‐two patients were …

Supraventricular Tachycardia Control with Tachylog II: Long‐Term Follow‐Up

AN Sulke, CA Bucknall, E Sowton - Pacing and Clinical …, 1990 - Wiley Online Library
SULKE, AN, ET AL.: Supraventricular Tachycardia Control with Tachylog 11: Long‐Term
Follow‐Up. Ten patients aged 16–63 years (mean 36.3) had the Siemens P56T “Tachylog II” …

Clinical Utility of Implantable Multiprogrammable Automatic Antitachycardia Pulse Generator as an External Device.

SS Barold, M Sweeney, MD Falkoff… - Pacing & Clinical …, 1981 - search.ebscohost.com
Focuses on the clinical utility of implantable multiprogrammable automatic antitachycardia
pulse generator as a external device. Potential of automatic antitachycardia pulse generator …

Multicenter long-term results of antitachycardia pacing for supraventricular tachycardias

L Kappenberger, H Valin, E Sowton - The American journal of cardiology, 1989 - Elsevier
This report describes the multicenter experience of the Tachylog antitachycardia pacemaker
(Siemens-Elema) in the treatment of drug-refractory, recurrent supraventricular arrhythmias …

The effect of chronic atrial overdrive suppression pacing on the incidence of supraventricular tachyarrhythmias

AH Shandling, R Crump, M Nolasco… - Clinical …, 1992 - Wiley Online Library
Chronic overdrive suppression pacing has been suggested as an effective adjunctive
method for reducing the incidence of cardiac tachyarrhythmias. Documentation of …

Importance of modes of electrical termination of ventricular tachycardia for the selection of implantable antitachycardia devices

B Waldecker, P Brugada, M Zehender… - The American journal of …, 1986 - Elsevier
Different implantable systems for electrical treatment of ventricular arrhythmias are available.
Information about mode of termination of ventricular tachycardia (VT) helps to select the …