Microbial corrosion in titanium-based dental implants: how tiny bacteria can create a big problem?
RC Costa, VL Abdo, PHC Mendes… - Journal of Bio-and Tribo …, 2021 - Springer
Microbiologically induced corrosion plays a key role in implanted materials survival,
especially those exposed to the oral environment. Despite considerable progress in this …
especially those exposed to the oral environment. Despite considerable progress in this …
Interruption of electrical conductivity of titanium dental implants suggests a path towards elimination of corrosion
AE Pozhitkov, D Daubert, A Brochwicz Donimirski… - PLoS …, 2015 - journals.plos.org
Peri-implantitis is an inflammatory disease that results in the destruction of soft tissue and
bone around the implant. Titanium implant corrosion has been attributed to the implant …
bone around the implant. Titanium implant corrosion has been attributed to the implant …
Evaluation of oral microbial corrosion on the surface degradation of dental implant materials
DA Siddiqui, L Guida, S Sridhar… - Journal of …, 2019 - Wiley Online Library
Abstract Background Titanium (Ti) dominates as the material of choice for dental implant
systems. Recently, titanium‐zirconium alloy (TiZr) and zirconia (ZrO₂) have emerged as …
systems. Recently, titanium‐zirconium alloy (TiZr) and zirconia (ZrO₂) have emerged as …
The role of bacterial corrosion on recolonization of titanium implant surfaces: An in vitro study
J Weller, P Vasudevan, B Kreikemeyer… - … Implant Dentistry and …, 2022 - Wiley Online Library
Background Inflammation triggered by bacterial biofilms in the surrounding tissue is a major
etiological factor for peri‐implantitis and subsequent implant failure. However, little is known …
etiological factor for peri‐implantitis and subsequent implant failure. However, little is known …
Spectroscopic and microscopic investigation of the effects of bacteria on dental implant surfaces
DC Rodrigues, S Sridhar, IM Gindri, DA Siddiqui… - RSC …, 2016 - pubs.rsc.org
The surface morphology and chemical composition of commercially pure titanium dental
implants and healing abutments exposed in vitro or in vivo to oral bacteria were studied …
implants and healing abutments exposed in vitro or in vivo to oral bacteria were studied …
Insight into corrosion of dental implants: from biochemical mechanisms to designing corrosion-resistant materials
BE Nagay, JM Cordeiro, VAR Barao - Current Oral Health Reports, 2022 - Springer
Abstract Purpose of Review Despite advanced technologies to avoid corrosion of dental
implants, the mechanisms toward the release of metals and their role in the onset of peri …
implants, the mechanisms toward the release of metals and their role in the onset of peri …
Lipopolysaccharide inhibits or accelerates biomedical titanium corrosion depending on environmental acidity
F Yu, O Addison, SJ Baker, AJ Davenport - International Journal of Oral …, 2015 - nature.com
Titanium and its alloys are routinely used as biomedical implants and are usually
considered to be corrosion resistant under physiological conditions. However, during …
considered to be corrosion resistant under physiological conditions. However, during …
Electrochemical treatment of contaminated titanium surfaces in vitro: An approach for implant surface decontamination
AA Al-Hashedi, M Laurenti, MN Abdallah… - ACS biomaterials …, 2016 - ACS Publications
Bacterial contamination on titanium implants can cause inflammation and eventually implant
failure. Currently used methods for decontamination of implants have demonstrated limited …
failure. Currently used methods for decontamination of implants have demonstrated limited …
[HTML][HTML] Microbiologically influenced corrosion can cause a dental implant rejection
E Hubenova, M Mitov, Y Hubenova - Electrochimica Acta, 2024 - Elsevier
In the present study, we apply electrochemical and molecular biology approaches to
establish whether microbiologically influenced corrosion (MIC) may be the reason for dental …
establish whether microbiologically influenced corrosion (MIC) may be the reason for dental …
Effect of oral bacteria on the mechanical behavior of titanium dental implants.
FJ Gil, A Rodriguez, E Espinar… - … Journal of Oral & …, 2012 - search.ebscohost.com
Purpose: This study sought to determine whether the mechanical properties of titanium
dental implants changed after exposure to bacteria. Materials and Methods: Two strains of …
dental implants changed after exposure to bacteria. Materials and Methods: Two strains of …
相关搜索
- dental implants microbial corrosion
- tiny bacteria microbial corrosion
- big problem microbial corrosion
- big problem tiny bacteria
- dental implants polymicrobial infections
- dental implants biochemical mechanisms
- effects of bacteria implant surfaces
- environmental acidity titanium corrosion
- oral bacteria on the mechanical behavior
- electrochemical treatment titanium surfaces
- elimination of corrosion electrical conductivity
- dental implants tiny bacteria
- dental implants big problem