Anti-tachycardia pacing efficacy in the setting of prolonged arrhythmia detection. New data from the advanceiii study

A Proclemer, M Gasparini, A Kloppe, M Lunati… - 2012 - Am Heart Assoc
Introduction: Shock therapy in ICD implanted population has been associated with
increased morbitdity and new programming strategies have been evaluated to reduce ICD …

Antitachycardia pacing in patients with implantable cardioverter defibrillators: how many attempts are useful?

R Fries, A Heisel, G Kalweit, J Jung… - Pacing and clinical …, 1997 - Wiley Online Library
The purpose of this study was to determine the termination and acceleration rates for 1 to 6
attempts of antitachycardia pacing (ATP) delivered by ICD in order to terminate …

Safety of antitachycardia pacing in patients with implantable cardioverter defibrillators and severely depressed left ventricular function

A Heisel, J NEUZNER, E Himmrich… - Pacing and Clinical …, 1995 - Wiley Online Library
The purpose of this study was to investigate the efficacy and safety of antitachycardia pacing
(ATP) in third‐generation implantable Cardioverter defibrillators (ICDs) for terminating …

Long-term follow up of patients treated with a software based antitachycardia pacemaker.

DT Connelly, MA de Belder, D Cunningham, AN Lopes… - Heart, 1993 - heart.bmj.com
INTRODUCTION--Over the past decade, several advances have been made in the
management of tachycardias by pacing techniques, but limited data are available on the …

Rationale and design of the OPTION study: optimal antitachycardia therapy in ICD patients without pacing indications

C Kolb, S Tzeis, M Sturmer, D Babuty… - Pacing and clinical …, 2010 - Wiley Online Library
Background: Implantable cardioverter‐defibrillators (ICDs) represent the treatment of choice
for primary and secondary prevention of sudden cardiac death but ICD therapy is also …

Antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with prophylactic cardioverter‐defibrillator therapy

W Grimm, E Plachta, B Maisch - Pacing and clinical …, 2006 - Wiley Online Library
Aims: Antitachycardia pacing (ATP) has not routinely been used in patients who received
implantable cardioverter defibrillators (ICDs) for primary prevention of sudden death. This …

Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study

RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
Aims Little is known about the optimal number of antitachycardia pacing (ATP) attempts to
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …

Clinical predictors of antitachycardia pacing response in implantable cardioverter defibrillator patients

JW Harrison, A Manola, LK Kalluri… - Pacing and Clinical …, 2019 - Wiley Online Library
Background Antitachycardia pacing (ATP) provides safe and painless termination of
reentrant ventricular arrhythmias in patients with implantable cardioverter defibrillator (ICDs) …

Incremental programming of atrial anti-tachycardia pacing therapies in bradycardia-indicated patients: effects on therapy efficacy and atrial tachyarrhythmia burden

B Hügl, CW Israel, C Unterberg, T Lawo… - EP …, 2003 - academic.oup.com
Aims Efficacy of pace-termination of atrial arrhythmias (ATP) may depend on atrial cycle
length and regularity. Whether device programming of ATP therapies can improve ATP …

[HTML][HTML] Atrial fibrillation and pacing algorithms

P Terranova, B Severgnini, P Valli… - Indian Pacing and …, 2006 - ncbi.nlm.nih.gov
Pacing prevention algorithms have been introduced in order to maximize the benefits of
atrial pacing in atrial fibrillation prevention. It has been demonstrated that algorithms actually …