Antitachycardia pacing in patients with left ventricular dysfunction and hemodynamically unstable arrhythmias
M Oliveira, E Antunes, N da Silva, S Martins… - … : Orgao Oficial da …, 1999 - europepmc.org
Objective To assess the safety and efficacy of ATP in ICD carriers with ischemic cardiopathy
and systolic dysfunction of the left ventricle (LV) presenting VT badly tolerated …
and systolic dysfunction of the left ventricle (LV) presenting VT badly tolerated …
Empirical versus tested antitachycardia pacing in implantable cardioverter defibrillators: a prospective study including 200 patients
A Schaumann, F Mühlen, B Herse, BD Gonska… - Circulation, 1998 - Am Heart Assoc
Background—Implantable cardioverter-defibrillators (ICDs) reduce the risk of sudden
cardiac death. The objective of this study was to evaluate whether testing of antitachycardia …
cardiac death. The objective of this study was to evaluate whether testing of antitachycardia …
Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging
W Schoels, D Steinhaus, WB Johnson, G O'Hara… - Heart Rhythm, 2007 - Elsevier
BACKGROUND: Previous studies in implantable cardioverter-defibrillator (ICD) patients
demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular …
demonstrated the efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular …
Pace‐termination and pacing for prevention of atrial tachyarrhythmias: results from a multicenter study with an implantable device for atrial therapy
CW Israel, B Hügl, C Unterberg, T Lawo… - Journal of …, 2001 - Wiley Online Library
Pacing for Treatment of Atrial Tachyarrhythmias. Introduction: Patients with bradycardia
requiring permanent pacing frequently suffer from additional atrial tachyarrhythmias (ATs) …
requiring permanent pacing frequently suffer from additional atrial tachyarrhythmias (ATs) …
[HTML][HTML] Impact of device programming on the success of the first anti-tachycardia pacing therapy: An anonymized large-scale study
S Shakibfar, O Krause, C Lund-Andersen, F Strycko… - Plos one, 2019 - journals.plos.org
Background Antitachycardia pacing (ATP) is an effective treatment for ventricular
tachycardia (VT). We evaluated the efficacy of different ATP programs based on a large …
tachycardia (VT). We evaluated the efficacy of different ATP programs based on a large …
[HTML][HTML] Effectiveness of changing conventional implantable cardioverter-defibrillator settings to intrinsic antitachycardia pacing–like settings in the treatment of …
M Tachibana, A Hayashida, K Banba, M Arimichi… - HeartRhythm Case …, 2022 - Elsevier
Effectiveness of changing conventional implantable cardioverter-defibrillator settings to intrinsic
antitachycardia pacing–like settings in the treatment of ventricular tachycardia in patients with …
antitachycardia pacing–like settings in the treatment of ventricular tachycardia in patients with …
Antitachycardia pacing: an overview
L Horwood, S VanRiper, T Davidson - American Journal of Critical Care, 1995 - AACN
Ventricular tachycardia is the most common life-threatening tachyarrhythmia seen in patients
with structural heart disease. In the past 10 years, many thousands of lives have been saved …
with structural heart disease. In the past 10 years, many thousands of lives have been saved …
Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients
S Yanagisawa, Y Inden, Y Sato… - Journal of …, 2024 - Wiley Online Library
Introduction Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia
pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT) …
pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT) …
Differences in ventricular tachyarrythmias and antitachycardia pacing effectiveness according to the ICD indication (primary versus secondary prevention): an analysis …
J Jiménez-Candil, J Hernández, A Martín… - Journal of Interventional …, 2015 - Springer
Purpose To determine whether monomorphic ventricular tachycardias (VTs) have different
characteristics and/or responses to antitachycardia pacing (ATP) with respect to the …
characteristics and/or responses to antitachycardia pacing (ATP) with respect to the …
Effectiveness of antitachycardia pacing therapy after primary prophylaxis implantation of implantable defibrillators in coronary artery disease patients
A Maciąg, A Przybylski, M Sterliński… - Advances in Medical …, 2014 - Elsevier
Purpose Effectiveness of implantable defibrillators (ICD) has been proven with large
randomized trials. Unfortunately, ICD discharge is painful and potentially threatening for the …
randomized trials. Unfortunately, ICD discharge is painful and potentially threatening for the …