[HTML][HTML] Novel ventricular tachyarrhythmia detection enhancement detects undertreated life-threatening arrhythmias

BL Wilkoff, LD Sterns, MS Katcher, G Upadhyay… - Heart Rhythm O2, 2022 - Elsevier
Background Ventricular tachyarrhythmias (VTA) with low and varying signal amplitudes and
morphologies may not be successfully identified utilizing traditional implantable cardioverter …

[PDF][PDF] Ventricular tachycardia versus ventricular fibrillation: discrimination by current antitachycardia devices

SA Caswell, JR Shiu, B Pariseau… - Journal of …, 1996 - academia.edu
Materials and Methods This study assessed the programmable parameters for proper
distinction between VT and VF in three commercially approved devices. Detection schemes …

A fully automatic, implantable cardioverter-defibrillator algorithm to prevent inappropriate detection of ventricular tachycardia or fibrillation due to T-wave oversensing …

J Cao, JM Gillberg, CD Swerdlow - Heart Rhythm, 2012 - Elsevier
BACKGROUND: T-wave oversensing (TWOS) may cause inappropriate shocks in patients
with implantable cardioverter-defibrillator (ICD). Programming options to prevent TWOS are …

Failure to treat life-threatening ventricular tachyarrhythmias in contemporary implantable cardioverter–defibrillators: Implications for strategic programming

AM Thøgersen, JM Larsen, JB Johansen… - Circulation …, 2017 - Am Heart Assoc
Background: In clinical trials, manufacturer-specific, strategic programming of implantable
cardioverter–defibrillators (ICDs), including faster detection rates, reduces unnecessary …

An annotated ventricular tachycardia (VT) alarm database: Toward a uniform standard for optimizing automated VT identification in hospitalized patients

MM Pelter, MG Carey, S Al‐Zaiti… - Annals of …, 2023 - Wiley Online Library
Background False ventricular tachycardia (VT) alarms are common during in‐hospital
electrocardiographic (ECG) monitoring. Prior research shows that the majority of false VT …

Automated analysis of spontaneously occurring arrhythmias by implantable devices: limitations of using rate and timing features alone

SA Caswell, LA DiCarlo, CMJ Chiang… - Journal of …, 1994 - Elsevier
Real-time automated systems for arrhythmia analysis by implantable antitachycardia
devices have been designed to incorporate two-channel rate criteria with intracavitary atrial …

Ventricular tachycardias above the initially programmed tachycardia detection interval in patients with implantable cardioverter-defibrillators: incidence, prediction and …

D Bänsch, M Castrucci, D Böcker, G Breithardt… - Journal of the American …, 2000 - jacc.org
OBJECTIVES This retrospective study was performed to provide data on ventricular
tachycardias (VT) with a cycle length longer than the initially programmed tachycardia …

Multiple state morphology-based system detecting ventricular tachycardia and supraventricular tachycardia

W Hsu, AF Marcovecchio - US Patent 6,430,435, 2002 - Google Patents
BACKGROUND Recent prospective clinical trials have shown that cardioVerter-
defibrillators, Such as implantable cardioverter defibrillators (ICDs), reduce Sudden …

Detection of the fingerprint of the electrophysiological abnormalities that increase vulnerability to life-threatening ventricular arrhythmias

ME Cain, RM Arthur, JW Trobaugh - Journal of interventional cardiac …, 2003 - Springer
Reduction of sudden death requires accurate identification of patients at risk for ventricular
tachycardia (VT) and effective therapies. The Multicenter Unsustained Tachycardia Trial and …

[HTML][HTML] Troubleshooting implantable cardioverter-defibrillators: an overview for physicians who are not electrophysiologists

M Saeed - Texas Heart Institute Journal, 2011 - ncbi.nlm.nih.gov
If device interrogation reveals intracardiac electrograms (EGMs) consistent with SVT, both
device reprogramming to prevent recurrent shocks and treatment of SVT are needed. Atrial …