Target flow-pressure operating range for designing a failing Fontan cavopulmonary support device

M Farahmand, MN Kavarana… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
Fontan operation as the current standard of care for the palliation of single ventricle defects
results in significant late complications. Using a mechanical circulatory device for the right …

Risks and benefits of using a commercially available ventricular assist device for failing Fontan cavopulmonary support: a modeling investigation

M Farahmand, MN Kavarana… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Fontan patients often develop circulatory failure and are in desperate need of a therapeutic
solution. A blood pump surgically placed in the cavopulmonary pathway can substitute the …

[HTML][HTML] Computational fluid dynamic simulations of a cavopulmonary assist device for failing Fontan circulation

WCP Lin, MG Doyle, SL Roche, O Honjo… - The Journal of thoracic …, 2019 - Elsevier
Objectives Adult patients who have undergone the Fontan procedure are highly vulnerable
to gradual, progressive circulatory failure, and options to reverse this situation are few. A …

A long-term mechanical cavopulmonary support device for patients with Fontan circulation

M Granegger, B Thamsen, EJ Hubmann, Y Choi… - Medical engineering & …, 2019 - Elsevier
In patients with a single ventricle, failure of the cardiovascular system may be prevented by
substituting the missing sub-pulmonary ventricle with a pump. The aim of this study was to …

[图书][B] Cavopulmonary assist device to bridge failing Fontan circulations

WCP Lin - 2018 - search.proquest.com
A novel cavopulmonary assist strategy with a multi-lumen cannula powered by an external
centrifugal pump is proposed for use in failing Fontan patients. Steady-state computational …

A sensorless physiologic control strategy for continuous flow cavopulmonary circulatory support devices

Y Wang, J Peng, MD Rodefeld, Y Luan… - … Signal Processing and …, 2020 - Elsevier
Objective Mechanical circulatory support devices using continuous flow blood pump
technologies are currently being developed to provide cavopulmonary support in patients …

A numerical simulation comparing a cavopulmonary assist device and VA ECMO for failing Fontan support

PL Hsu, D Wang, C Ballard-Croft, D Xiao… - ASAIO …, 2017 - journals.lww.com
A cavopulmonary assist device (CPAD) has been developed for failing Fontan support. This
CPAD pumps blood from superior/inferior vena cavae (SVC/IVC) to pulmonary artery. In this …

Steady flow analysis of mechanical cavopulmonary assistance in MRI‐derived patient‐specific Fontan configurations

EA Downs, WB Moskowitz, AL Throckmorton - Artificial Organs, 2012 - Wiley Online Library
This numerical study examined the performance of an intravascular axial flow blood pump
for mechanical hemodynamic support of patients in the setting of Fontan failure, which …

A viable therapeutic option: mechanical circulatory support of the failing Fontan physiology

AL Throckmorton, S Lopez-Isaza, EA Downs… - Pediatric …, 2013 - Springer
A blood pump specifically designed to augment flow from the great veins through the lungs
would ameliorate the poor physiology of the failing univentricular circulation and result in a …

Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support

W Yang, TA Conover, RS Figliola, GA Giridharan… - Scientific Reports, 2023 - nature.com
Patients with single ventricle defects undergoing the Fontan procedure eventually face
Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are …