Extravascular Implantable Cardioverter-Defibrillator Sensing and Detection in a Large Global Population
C Swerdlow, J Gillberg, LVA Boersma… - JACC: Clinical …, 2024 - Elsevier
Background The extravascular (EV) implantable cardioverter-defibrillator (ICD) includes
features to address sensing and arrhythmia detection challenges presented by its substernal …
features to address sensing and arrhythmia detection challenges presented by its substernal …
Design and preliminary results of sensing and detection for an extravascular implantable cardioverter-defibrillator
CD Swerdlow, X Zhang, R Sawchuk, S Greenhut… - Clinical …, 2021 - jacc.org
Objectives This study reports the sensing and arrhythmia detection performance of a novel
extravascular (EV) implantable cardioverter-defibrillator (ICD) in a first-in-human pilot study …
extravascular (EV) implantable cardioverter-defibrillator (ICD) in a first-in-human pilot study …
Chronic follow-up from the pilot study of a novel substernal extravascular implantable cardioverter-defibrillator
Abstract Background The investigational Extravascular Implantable Cardioverter Defibrillator
(EV ICD) is an implantable defibrillator with defibrillation and pacing therapies, including the …
(EV ICD) is an implantable defibrillator with defibrillation and pacing therapies, including the …
[HTML][HTML] Ventricular tachycardia slower than the rate cut-off of a subcutaneous cardiac defibrillator sensed and successfully treated as a result of oversensing
Ventricular tachycardia slower than the rate cut-off of a subcutaneous cardiac defibrillator
sensed and successfully treated as a result of oversensing - ScienceDirect Skip to main …
sensed and successfully treated as a result of oversensing - ScienceDirect Skip to main …
Three-year chronic follow-up from the pilot study of a substernal extravascular implantable cardioverter-defibrillator
Implantable cardioverter-defibrillators (ICDs) reduce mortality in patients at risk of sudden
cardiac death. 1–3 Transvenous lead-related complications 4–6 have prompted the …
cardiac death. 1–3 Transvenous lead-related complications 4–6 have prompted the …
First-in-human chronic implant experience of the substernal extravascular implantable cardioverter-defibrillator
Objectives The aim of this study was to evaluate the safety and performance of an
extravascular (EV) implantable cardioverter-defibrillator (ICD). Background Limitations of …
extravascular (EV) implantable cardioverter-defibrillator (ICD). Background Limitations of …
What is ventricular fibrillation undersensing?
ML Brown - Journal of Electrocardiology, 2018 - Elsevier
Abstract Ventricular fibrillation (VF), uninterrupted, is fatal within minutes. Implantable
cardioverter defibrillators (ICDs) sense ventricular electrograms (EGMs) during VF and …
cardioverter defibrillators (ICDs) sense ventricular electrograms (EGMs) during VF and …
Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators: prospective comparison of different lead system–device combinations
A Natale, J Sra, K Axtell, M Akhtar, K Newby, V Kent… - Circulation, 1996 - Am Heart Assoc
Background The purpose of this study was to prospectively analyze redetection problems
after unsuccessful shock with different lead systems and devices. Methods and Results We …
after unsuccessful shock with different lead systems and devices. Methods and Results We …
[引用][C] PO-05-052 COMPARISON OF SIMULTANEOUS, MATCHED PROGRAMMING AMBULATORY RHYTHM DETECTION BETWEEN A NOVEL EXTRAVASCULAR …
Background A novel extravascular (EV) ICD lead (AtaCor Medical, San Clemente, CA) is
under development for sensing and defibrillation of ventricular tachyarrhythmias (VF) using …
under development for sensing and defibrillation of ventricular tachyarrhythmias (VF) using …
Implantable defibrillators with enhanced detection algorithms: detection performance and safety results from the PainFree SST study
CG Wollmann, T Lawo, V Kuehlkamp… - Pacing and Clinical …, 2014 - Wiley Online Library
Background Implantable defibrillators (ICD) are highly effective in reducing arrhythmia‐
related mortality. ICD shock therapy has been shown to increase psychological distress …
related mortality. ICD shock therapy has been shown to increase psychological distress …