Anti‐tachycardia pacing for non‐fast and fast ventricular tachycardias in individual Japanese patients: from Nippon‐storm study
M Chinushi, O Saitoh, H Furushima… - Journal of …, 2021 - Wiley Online Library
Background Anti‐tachycardia pacing (ATP) delivered from an implantable device is a useful
tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for those patients …
tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for those patients …
Patient‐by‐patient basis anti‐tachycardia pacing for fast ventricular tachycardia with structural heart diseases
M Chinushi, H Furushima, O Saitoh… - Pacing and Clinical …, 2020 - Wiley Online Library
Background Anti‐tachycardia pacing (ATP) delivered from an implantable device is an
important tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for fast VT …
important tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for fast VT …
Effectiveness of first versus successive antitachycardia pacing attempts: predictors and clinical consequences
J Jiménez-Candil, O Durán, J Núñez, L Bravo… - Journal of Interventional …, 2019 - Springer
Purpose Antitachycardia pacing (ATP) terminates the majority (but not all) of slow ventricular
tachycardias (S-VT) with a cycle length (CL)> 320 ms. Usually, several ATP therapies are …
tachycardias (S-VT) with a cycle length (CL)> 320 ms. Usually, several ATP therapies are …
Long-term efficacy of antitachycardia pacing for treatment of ventricular tachycardia in patients with implantable cardioverter/defibrillator
M Fiek, E Hoffmann, U Dorwarth, D Müller… - Zeitschrift fur …, 1999 - europepmc.org
Conclusions First, ATP is a highly effective therapy, independent of patients characteristics.
Second, short VT cycle length and long ATP coupling intervals were identified as predictors …
Second, short VT cycle length and long ATP coupling intervals were identified as predictors …
Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients
S Yanagisawa, Y Inden, Y Sato… - Journal of …, 2024 - Wiley Online Library
Introduction Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia
pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT) …
pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT) …
Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study
RP Martins, H Blangy, L Muresan, L Freysz… - Europace, 2012 - academic.oup.com
Aims Little is known about the optimal number of antitachycardia pacing (ATP) attempts to
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …
programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long …
Efficacy of Anti-Tachycardia Pacing for Terminating Fast Ventricular Tachycardia in Japanese Implantable Cardioverter Defibrillator Patients–Primary Results of the …
T Watanabe, K Inoue, K Kashiwase, T Mine… - Circulation …, 2014 - jstage.jst.go.jp
Background: Anti-tachycardia pacing (ATP) delivered by implantable cardioverter
defibrillators (ICD) safely avoids painful shocks with minimum risk of tachycardia …
defibrillators (ICD) safely avoids painful shocks with minimum risk of tachycardia …
Characteristics of ventricular tachyarrhythmias and their susceptibility to antitachycardia pacing termination in patients with ischemic and nonischemic cardiomyopathy …
A Cheng, B Joung, ML Brown, J Koehler… - Journal of …, 2020 - Wiley Online Library
Abstract Background Implantable cardioverter defibrillators (ICDs) reduce all‐cause
mortality among cardiomyopathy patients. Whether or not antitachycardia pacing (ATP) is …
mortality among cardiomyopathy patients. Whether or not antitachycardia pacing (ATP) is …
What factors lead to the acceleration of ventricular tachycardia during antitachycardia pacing?—Results from over 1000 episodes
Y Fang, K Gu, B Yang, W Ju, H Chen, M Li… - Journal of …, 2018 - Wiley Online Library
Introduction Ventricular tachycardia (VT) acceleration due to antitachycardia pacing (ATP)
therapy could be often observed in patients with implantable cardioverter defibrillator (ICD) …
therapy could be often observed in patients with implantable cardioverter defibrillator (ICD) …
Efficacy of intrinsic antitachycardia pacing for ventricular tachycardia refractory to conventional burst pacing: A case series
T Kamakura, N Ueda, M Wada… - Journal of …, 2023 - Wiley Online Library
Intrinsic antitachycardia pacing (iATP) is a novel automated ventricular ATP algorithm that
designs ATP sequences based on the analysis of prior failed ATP. Real‐world data on the …
designs ATP sequences based on the analysis of prior failed ATP. Real‐world data on the …