Design and preliminary results of sensing and detection for an extravascular implantable cardioverter-defibrillator

CD Swerdlow, X Zhang, R Sawchuk, S Greenhut… - Clinical …, 2021 - jacc.org
Objectives This study reports the sensing and arrhythmia detection performance of a novel
extravascular (EV) implantable cardioverter-defibrillator (ICD) in a first-in-human pilot study …

Undetected ventricular fibrillation in transvenous implantable cardioverter-defibrillators: prospective comparison of different lead system–device combinations

A Natale, J Sra, K Axtell, M Akhtar, K Newby, V Kent… - Circulation, 1996 - Am Heart Assoc
Background The purpose of this study was to prospectively analyze redetection problems
after unsuccessful shock with different lead systems and devices. Methods and Results We …

Sensing and detection in Medtronic implantable cardioverter defibrillators.

ML Brown, CD Swerdlow - Herzschrittmachertherapie & …, 2016 - europepmc.org
Ensuring sensing and detection of ventricular tachycardia (VT) and ventricular fibrillation
(VF) was a prerequisite for the clinical trials that established the survival benefit of …

Comparison of bipolar and integrated sensing for redetection of ventricular fibrillation

M Cooklin, RV Tummala, RW Peters, SR Shorofsky… - American Heart …, 1999 - Elsevier
Background Implantable cardioverter-defibrillator function is critically dependent on reliable
sensing of intracardiac signals. Lead systems that use integrated sensing, in which the distal …

Head‐to‐head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: the START study

MR Gold, DA Theuns, BP Knight… - Journal of …, 2012 - Wiley Online Library
Arrhythmia Detection with S‐ICD Versus Transvenous ICDs. Background: The development
of a totally subcutaneous implantable defibrillator (S‐ICD) system requires a new approach …

A new single chamber implantable defibrillator with atrial sensing: a practical demonstration of sensing and ease of implantation

D Bänsch, R Schneider, I Akin, CA Nienaber - JoVE (Journal of Visualized …, 2012 - jove.com
Implantable cardioverter-defibrillators (ICDs) terminate ventricular tachycardia (VT) and
ventricular fibrillation (VF) with high efficacy and can protect patients from sudden cardiac …

Ventricular fibrillation sensing and detection by implantable defibrillators: is one better than the others? A prospective, comparative study

P Panotopoulos, D Krum, K Axtell… - Journal of …, 2001 - Wiley Online Library
ICD Sensing During VF. Introduction: We prospectively compared the performance of the
sensing and detection systems of three leading defibrillator manufacturers: Medtronic …

Is defibrillation testing necessary for implantable transvenous defibrillators? defibrillation testing is necessary at the time of implantable cardioverter defibrillator …

AM Russo, MK Chung - Circulation: Arrhythmia and …, 2014 - Am Heart Assoc
DT assesses the electric integrity of the connections between the leads and pulse generator
and confirms reliable sensing, detection, and redetection in VF. opponents of DT note that …

Adjustment of maximum automatic sensitivity (automatic gain control) reduces inappropriate therapies in patients with implantable cardioverter defibrillators

M Niehaus, J Neuzner, J Vogt, T Korte… - Pacing and clinical …, 2002 - Wiley Online Library
NIEHAUS, M., et al.: Adjustment of Maximum Automatic Sensitivity (Automatic Gain Control)
Reduces Inappropriate Therapies in Patients with Implantable Cardioverter Defibrillators …

Determination of pacing capture in implantable defibrillators: benefit of evoked response detection using RV coil to can vector

V Splett, JM Trusty, DL Hayes… - Pacing and Clinical …, 2000 - Wiley Online Library
SPLETT, V., et al.: Determination of Pacing Capture in Implantable Defibrillators: Benefit of
Evoked Response Detection Using RV Coil to Can Vector. Automatic detection of capture in …