A new coated nitinol occluder for transcatheter closure of ventricular septal defects in a canine model

Y Zhou, F Chen, X Huang, X Zhao… - BioMed research …, 2013 - Wiley Online Library
Aims. This study evaluated feasibility and safety of implanting the polyester‐coated nitinol
ventricular septal defect occluder (pcVSDO) in the canine model. Methods and Results. VSD …

Fully biodegradable septal defect occluder—A double umbrella design

D Duong‐Hong, YD Tang, W Wu… - Catheterization and …, 2010 - Wiley Online Library
Current percutaneous devices for septal defect treatment are made of nondegradable
metallic and synthetic fabric materials. These devices are not ideal due to risks of future …

Preliminary experience in the use of CERA occluders for closure of different intracardiac and extracardiac shunts.

R Fiszer, M Szkutnik, B Chodor… - The Journal of Invasive …, 2014 - europepmc.org
Background Transcatheter closure has become the method of choice for treatment of many
heart defects. Recently, Lifetech Scientific introduced the Cera occluder (CO), a self …

A Novel Biodegradable Septal Defect Occluder the “Chinese Lantern” Design, Proof of Concept

W Wu, J Yip, YD Tang, V Khoo, JF Kong… - …, 2011 - journals.sagepub.com
Objective Atrial septal defect (ASD) is a general term used to describe an opening in the
atrial septum that divides the two atria; unless the hole is occluded, it can give rise to serious …

Asymmetric occluder in minimal-invasive surgical device closure of ventricular septal defects

Q Wu, L Gao, X Xu, T Zhao, J Yang, X Wang… - Zhong nan da xue …, 2013 - europepmc.org
Objective To discuss the suitable types of ventricular septal defects for asymmetric
occluders, and elucidate the critical role of echocardiography in choosing occluders, guiding …

Retrieval of large Occlutech Figula Flex septal defect occluders using a commercially available bioptome: proof of concept

S Georgiev, D Tanase, T Genz, P Ewert… - Cardiology in the …, 2018 - cambridge.org
ObjectivesThis study aimed to develop a method for retrieval of the new meshed nitinol atrial
septal defect occluders–Ceraflex and Occlutech. BackgroundThe newly developed atrial …

Animal experimental study of the fully biodegradable atrial septal defect (ASD) occluder

Y Zhu, X Huang, J Cao, J Hu, Y Bai… - BioMed Research …, 2012 - Wiley Online Library
This study was conducted to evaluate the feasibility, safety, biocompatibility, and
degradation features of a fully biodegradable occluder for closure of atrial septal defect …

Early malfunction of polyvinyl alcohol membrane of septal occluder

MG Ramoğlu, T Uçar, E Tutar - Catheterization and …, 2016 - Wiley Online Library
Percutaneous device closure of atrial septal defect (ASD) is now considered the choice of
treatment. Numerous devices with advantages/disadvantages are currently available and …

R ecent development of transcatheter closure of atrial septal defect and patent foramen ovale with occluders

B Tang, F Su, X Sun, Q Wu, Q Xing… - Journal of Biomedical …, 2018 - Wiley Online Library
Atrial septal defect (ASD) and patent foramen ovale (PFO) are common clinical congenital
heart defects. As an effective method for the treatment of ASD and PFO, transcatheter …

Retrograde transcatheter closure of ventricular septal defect with Amplatzer Duct Occluder II

B Suligoj, N Cernic, M Zorc, M Noc, S Kar - Advances in Interventional …, 2016 - termedia.pl
One of the most feared complications of transcatheter closure of a perimembranous
ventricular septal defect (VSD) by the Amplatzer membranous occluder is atrioventricular …