Imaging breast microcalcifications using dark-field signal in propagation-based phase-contrast tomography

A Aminzadeh, BD Arhatari… - … on Medical Imaging, 2022 - ieeexplore.ieee.org
Breast microcalcifications are an important primary radiological indicator of breast cancer.
However, microcalcification classification and diagnosis may be still challenging for …

[HTML][HTML] X-ray phase-contrast computed tomography for soft tissue imaging at the imaging and medical beamline (IMBL) of the Australian synchrotron

BD Arhatari, AW Stevenson, B Abbey, YI Nesterets… - Applied Sciences, 2021 - mdpi.com
The Imaging and Medical Beamline (IMBL) is a superconducting multipole wiggler-based
beamline at the 3 GeV Australian Synchrotron operated by the Australian Nuclear Science …

Feasibility study of phase-contrast cone beam CT imaging systems

W Cai - 2009 - urresearch.rochester.edu
Attenuation-based x-ray imaging techniques have been developed for many decades. One
of the state-of-the-art imaging modalities is the cone beam computed tomography (CBCT) …

Clinical study in phase-contrast mammography: image-quality analysis

R Longo, M Tonutti, L Rigon… - … of the Royal …, 2014 - royalsocietypublishing.org
The first clinical study of phase-contrast mammography (PCM) with synchrotron radiation
was carried out at the Synchrotron Radiation for Medical Physics beamline of the Elettra …

[HTML][HTML] Dose-compatible grating-based phase-contrast mammography on mastectomy specimens using a compact synchrotron source

E Eggl, S Grandl, A Sztrόkay-Gaul, M Dierolf, C Jud… - Scientific reports, 2018 - nature.com
With the introduction of screening mammography, the mortality rate of breast cancer has
been reduced throughout the last decades. However, many women undergo unnecessary …

Quantitative characterization of ex vivo breast tissue via x-ray phase-contrast tomography

X Li, Z Chen, L Zhang, X Zhu, S Wang… - Journal of X-ray …, 2019 - content.iospress.com
BACKGROUND: Grating-based X-ray phase-contrast imaging (GPCI) has received growing
interests in recent years due to its high capability of visualizing soft tissue. Breast imaging is …

In-line phase contrast tomography of the breast with a dedicated micro-CT scanner

G Mettivier, K Bliznakova, A Sarno… - 2016 IEEE Nuclear …, 2016 - ieeexplore.ieee.org
We performed laboratory investigations of the image quality for in-line phase contrast micro
tomography dedicated to the breast, using a 3D breast phantom. We employed the cone …

Image quality and radiation dose in propagation based phase contrast mammography with a microfocus X-ray tube: A phantom study

R Castriconi, G Mettivier, P Russo - … IWDM 2016, Malmö, Sweden, June 19 …, 2016 - Springer
Digital mammography has limitations in sensitivity, in particular for patients with a dense
breast. Phase contrast techniques (phase contrast mammography, PCM) might increase the …

Dose efficiency consideration for volume-of-interest breast imaging using x-ray differential phase-contrast CT

W Cai, R Ning - Medical Imaging 2009: Physics of Medical …, 2009 - spiedigitallibrary.org
The newly developed differential phase-contrast (DPC) imaging technique has attracted
increasing interest among researchers. In a DPC system, the self-imaging effect and the …

In-line phase contrast mammography, phase contrast digital breast tomosynthesis, and phase contrast breast computed tomography with a dedicated ct scanner and a …

G Mettivier, F di Franco, A Sarno… - … on Radiation and …, 2020 - ieeexplore.ieee.org
We performed laboratory investigations of the image quality for 2-D [digital mammography
(DM)] and 3-D [digital breast tomosynthesis (DBT) and computed tomography (CT)] in-line …