Evaluation of a commercial colloidal gold assay for detection of influenza A and B virus in children's respiratory specimens

W Li, L Liu, L Chen, S Shang - Fetal and Pediatric Pathology, 2020 - Taylor & Francis
Objective: To evaluate the clinical diagnostic value of colloidal gold assay for detection of
influenza A and B virus. Methods: Results were compared for colloidal gold assay for …

The evaluation of colloidal gold immunochromatographic assay (GICA) for rapid diagnosis of influenza A disease

X Li, H Chen, J Wei, N Lv, L You - Clinical chemistry and laboratory …, 2011 - degruyter.com
Background: A low cost colloidal gold immunochromatographic assay (GICA) for rapid
detection of influenza A virus was developed. The assay was evaluated in this study …

Clinical evaluation of highly sensitive silver amplification immunochromatography systems for rapid diagnosis of influenza

K Mitamura, H Shimizu, M Yamazaki, M Ichikawa… - Journal of virological …, 2013 - Elsevier
In this study, the clinical usefulness of silver amplification immunochromatography (SAI)
influenza virus detection kits, which employed a photographic development technology to …

Development of immunochromatographic colloidal gold test strip for rapid detection of Haemophilus influenzae in clinical specimens

MM Kong, B Yang, CJ Gong, H Wang… - Journal of applied …, 2017 - academic.oup.com
Aims A simple and fast test strip for simultaneous detection of Haemophilus influenzae,
based on the theory of colloidal gold immunochromatography was developed. Methods and …

Comparison of a commercial qualitative real-time RT-PCR kit with direct immunofluorescence assay (DFA) and cell culture for detection of influenza A and B in …

F Gharabaghi, R Tellier, R Cheung, C Collins… - Journal of Clinical …, 2008 - Elsevier
BACKGROUND: Institutional pandemic planning prompted a study of the molecular
detection of influenza virus from respiratory specimens in children, compared to …

A strip test for the optical determination of influenza virus H3 subtype using gold nanoparticle coated polystyrene latex microspheres

X Liu, J Yang, Q Li, Y Wang, Y Wang, G Li, J Shi… - Microchimica Acta, 2020 - Springer
A strip test is described for the optical determination of influenza virus H3 subtype. It utilizes
gold nanoparticle (AuNP) coated polystyrene latex microspheres (PS) as the label and a …

Evaluation of a new dot blot enzyme immunoassay (directigen flu A+ B) for simultaneous and differential detection of influenza a and B virus antigens from respiratory …

J Reina, E Padilla, F Alonso… - Journal of clinical …, 2002 - Am Soc Microbiol
We report a prospective evaluation of a new dot blot enzyme immunoassay (EIA) method for
the direct, rapid, qualitative, simultaneous, and differential detection of the influenza A (IA) …

[HTML][HTML] Comparison of a new gold immunochromatographic assay for the rapid diagnosis of the novel influenza A (H7N9) virus with cell culture and a real-time …

C Jin, N Wu, X Peng, H Yao, X Lu, Y Chen… - BioMed Research …, 2014 - hindawi.com
We assessed a colloidal gold immunochromatographic assay (GICA) for rapid detection of
influenza A (H7N9) and compared it with reverse-transcription-polymerase chain reaction …

A highly sensitive europium nanoparticle-based immunoassay for detection of influenza A/B virus antigen in clinical specimens

P Zhang, SV Vemula, J Zhao, B Du… - Journal of clinical …, 2014 - Am Soc Microbiol
We report the development of a novel europium nanoparticle-based immunoassay (ENIA)
for rapid detection of influenza A and influenza B viruses. The ENIA demonstrated …

The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance

TMP Hewa, GA Tannock, DE Mainwaring… - Journal of virological …, 2009 - Elsevier
Current methods for the accurate diagnosis of influenza based on culture of the virus or PCR
are highly sensitive and specific but require specialised laboratory facilities and highly …