Intracochlear pressure and derived quantities from a three-dimensional model

YJ Yoon, S Puria, CR Steele - The Journal of the Acoustical Society of …, 2007 - pubs.aip.org
(2001)] measured gerbil intracochlear pressure and provided approximations for the
following derived quantities:(1) basilar membrane velocity,(2) pressure across the organ of …

Measurement of the hydrostatic pressures of the cochlear compartments

AM Feldman, HR Bittner, SW Brusilow - Neurological research, 1979 - Taylor & Francis
A micropressure transducer (sensitive to 0.1 cm H2O) utilizing a manual servo nulling
system and a micropipette (tip diameter 12–20 μ m) was designed in order to measure …

Intracochlear pressure measurements during acoustic shock wave exposure

NT Greene, MA Alhussaini, JR Easter, TF Argo IV… - Hearing research, 2018 - Elsevier
Introduction Injuries to the peripheral auditory system are among the most common results of
high intensity impulsive acoustic exposure. Prior studies of high intensity sound transmission …

Assessing the Accuracy of Preclinical Evaluation Techniques for Bone Conduction Devices

I Wils, T Putzeys - … Congress on Bone Conduction Hearing and …, 2023 - lirias.kuleuven.be
Objectives: The effectiveness of new bone conduction devices is usually assessed by
experimentally measuring the promontory velocity (VProm) or the intracochlear differential …

Estimation on the influence of placement on bone conduction transmission by ear-canal sound pressure

X Qin, S Otsuka, S Nakagawa - Acoustical Science and Technology, 2020 - jstage.jst.go.jp
2. Experiment Six subjects with normal hearing (four males and two females) with an
average age of 22 years participated in the measurements. All measurements were …

Three-dimensional representation of the human cochlea using micro-computed tomography data: presenting an anatomical model for further numerical calculations

K Braun, F Böhnke, T Stark - Acta oto-laryngologica, 2012 - Taylor & Francis
Conclusion: We present a complete geometric model of the human cochlea, including the
segmentation and reconstruction of the fluid-filled chambers scala tympani and scala …

Follow-up of sound pressure level at the tympanic membrane at varying impedance of the tympanic membrane-ossicular system

J Hartwein - HNO, 1992 - europepmc.org
We investigated the influence of varying compliance of the tympanic membrane on the
sound pressure level of the human ear canal using a model with adjustable compliance …

The influence of a cochlear implant electrode on the mechanical function of the inner ear

AM Huber, SJ Hoon, B Sharouz, B Daniel… - Otology & …, 2010 - journals.lww.com
Background: With the use of standard electrodes in cochlear implantation, residual acoustic
hearing is markedly reduced or even lost. Possible reasons for this loss are direct …

Impedances of the inner and middle ear estimated from intracochlear sound pressures in normal human temporal bones

DL Frear, X Guan, C Stieger, JJ Rosowski… - Hearing research, 2018 - Elsevier
For almost a decade, we have measured intracochlear sound pressures evoked by air
conducted (AC) sound presented to the ear canal in many fresh human cadaveric …

[引用][C] FIRST RESULTS OF ANALYSIS OF SOUND-TRANSMISSION THROUGH THE RECONSTRUCTED MIDDLE-EAR WITH AN INNER-EAR HYDROPHONE

KB Huttenbrink, H Hudde - HNO, 1994 - … 175 FIFTH AVE, NEW YORK, NY …