[HTML][HTML] The no-touch saphenous vein is an excellent alternative conduit to the radial artery 8 years after coronary artery bypass grafting: a randomized trial

M Dreifaldt, JD Mannion, H Geijer, M Lidén… - The Journal of Thoracic …, 2021 - Elsevier
Background In 2004, a prospective randomized trial demonstrated that after 3 years,
saphenous veins (SVs) harvested with a no touch (NT) technique had a greater patency …

Saphenous veins in coronary artery bypass grafting need external support

N Samano, D Souza… - … and Thoracic Annals, 2021 - journals.sagepub.com
The saphenous vein is the most commonly used conduit for coronary artery bypass grafting.
Arterial grafts are harvested with the outer pedicle intact whereas saphenous veins are …

Does a 'no-touch'technique result in better vein patency?

AH Sepehripour, OA Jarral, AR Shipolini… - Interactive …, 2011 - academic.oup.com
A best evidence topic was written according to a structured protocol. The question
addressed was whether harvesting the saphenous vein (SV) as a conduit for coronary artery …

The patency of sequential and individual vein coronary bypass grafts: a systematic review

J Li, Y Liu, J Zheng, T Bai, Y Liu, X Wang, N Liu… - The Annals of thoracic …, 2011 - Elsevier
BACKGROUND: Saphenous vein grafts continue to be the backbone of daily coronary
revascularization practice, but controversy still exists about whether to use them as an …

[HTML][HTML] Impact of endoscopic versus open saphenous vein harvest technique on late coronary artery bypass grafting patient outcomes in the ROOBY (Randomized …

MA Zenati, AL Shroyer, JF Collins, B Hattler… - The Journal of thoracic …, 2011 - Elsevier
OBJECTIVE: In the Randomized On/Off Bypass (ROOBY) Trial, the efficacy of on-pump
versus off-pump coronary artery bypass grafting was evaluated. This ROOBY Trial planned …

[HTML][HTML] Composite Y internal thoracic artery–saphenous vein grafts: short-term angiographic results and vasoreactive profile

M Gaudino, F Alessandrini, C Pragliola… - The Journal of Thoracic …, 2004 - Elsevier
BACKGROUND: The angiographic patency of composite Y internal thoracic artery–
saphenous vein grafts has not been investigated in detail. METHODS: Twenty-five patients …

'No-touch'saphenous vein harvesting improves graft performance in patients undergoing coronary artery bypass surgery: a journey from bedside to bench

MR Dashwood, JC Tsui - Vascular Pharmacology, 2013 - Elsevier
The saphenous vein is the most commonly used conduit in patients undergoing coronary
artery bypass surgery yet its patency is inferior to the internal thoracic artery. Vascular …

Improved patency in vein grafts harvested with surrounding tissue: results of a randomized study using three harvesting techniques

DSR Souza, MR Dashwood, JCS Tsui, D Filbey… - The Annals of thoracic …, 2002 - Elsevier
Background. The technique of harvesting the saphenous vein for coronary artery bypass
grafting influences the fate of vein grafts. The patency rate of a novel “no-touch” technique in …

External support for saphenous vein grafts in coronary artery bypass surgery: a randomized clinical trial

DJ Goldstein, JD Puskas, JH Alexander… - JAMA …, 2022 - jamanetwork.com
Importance Intimal hyperplasia and subsequent saphenous vein graft failure may have
significant adverse clinical effects in patients undergoing coronary artery bypass surgery …

Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?

NA Papakonstantinou, NG Baikoussis… - Annals of Cardiac …, 2016 - journals.lww.com
Coronary artery bypass grafting surgery effectively relieves signs and symptoms of
myocardial ischemia. The left internal thoracic artery (LITA) graft is the gold standard having …