In vitro examination of the ventriflo true pulse pump for failing fontan support

PM Trusty, M Tree, D Vincent, JP Naber… - Artificial …, 2019 - Wiley Online Library
The current methodology of Fontan palliation results in a one “pump” circulatory system with
passive flow to the lungs. Inherent hemodynamic differences exist between a biventricular …

[图书][B] Cavopulmonary assist device to bridge failing Fontan circulations

WCP Lin - 2018 - search.proquest.com
A novel cavopulmonary assist strategy with a multi-lumen cannula powered by an external
centrifugal pump is proposed for use in failing Fontan patients. Steady-state computational …

[HTML][HTML] Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support

W Yang, TA Conover, RS Figliola, GA Giridharan… - Scientific Reports, 2023 - nature.com
Patients with single ventricle defects undergoing the Fontan procedure eventually face
Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are …

Cavopulmonary support with a microaxial pump for the failing Fontan physiology

J Zhu, H Kato, YY Fu, L Zhao, C Foreman… - ASAIO …, 2015 - journals.lww.com
The number of patients with the failing Fontan physiology is increasing. We tested a novel in
situ microaxial pump (Impella) to support the failing atrio-pulmonary Fontan circulation in an …

In vitro examination of the HeartWare CircuLite ventricular assist device in the Fontan connection

M Tree, PM Trusty, TC Slesnick, A Yoganathan… - ASAIO …, 2017 - journals.lww.com
The failing Fontan physiology may benefit from ventricular assist device (VAD) mechanical
circulatory support, although a subpulmonary VAD placed at the Fontan connection has …

[HTML][HTML] Cavopulmonary assist: long-term reversal of the Fontan paradox

MD Rodefeld, A Marsden, R Figliola, T Jonas… - The Journal of thoracic …, 2019 - Elsevier
Objective Fontan circulatory inefficiency can be addressed by replacing the missing
subpulmonary power source to reverse the Fontan paradox. An implantable cavopulmonary …

[HTML][HTML] An in vitro analysis of the PediMag and CentriMag for right-sided failing Fontan support

PM Trusty, M Tree, K Maher, TC Slesnick… - The Journal of Thoracic …, 2019 - Elsevier
Objective Right-sided mechanical circulatory support for failing Fontan physiology has been
largely unsuccessful due to inherent hemodynamic differences between these patients and …

[HTML][HTML] Experimental and numeric investigation of Impella pumps as cavopulmonary assistance for a failing Fontan

CM Haggerty, F Fynn-Thompson… - The Journal of thoracic …, 2012 - Elsevier
OBJECTIVE: This study sought to evaluate the performance of microaxial ventricular assist
devices for the purposes of supporting failing Fontan physiology by decreasing central …

[HTML][HTML] Computational fluid dynamic simulations of a cavopulmonary assist device for failing Fontan circulation

WCP Lin, MG Doyle, SL Roche, O Honjo… - The Journal of thoracic …, 2019 - Elsevier
Objectives Adult patients who have undergone the Fontan procedure are highly vulnerable
to gradual, progressive circulatory failure, and options to reverse this situation are few. A …

A sensorless physiologic control strategy for continuous flow cavopulmonary circulatory support devices

Y Wang, J Peng, MD Rodefeld, Y Luan… - … Signal Processing and …, 2020 - Elsevier
Objective Mechanical circulatory support devices using continuous flow blood pump
technologies are currently being developed to provide cavopulmonary support in patients …