Cochlear coordinates in regard to cochlear implantation: a clinically individually applicable 3 dimensional CT-based method

BM Verbist, RMS Joemai, JJ Briaire… - Otology & …, 2010 - journals.lww.com
Setting: Cochlear implant (CI)/tertiary referral center. Subjects: Twenty-five patients
implanted with an Advanced Bionics HiRes90K HiFocus1J CI. Study Design/Main Outcome …

Cochlear coordinates in regard to cochlear implantation: a clinically individually applicable 3 dimensional CT-based method.

BM Verbist, RM Joemai, JJ Briaire… - … : Official Publication of …, 2010 - europepmc.org
Results The angular position of the center of the round window is 34.6+/-0.4 degrees
(standard deviation) with an intraclass coefficient of 1.00. The intraclass coefficient for …

[引用][C] Cochlear coordinates in regard to cochlear implantation: a clinically individually applicable 3 dimensional CT-based method.

BM Verbist, RM Joemai, JJ Briaire, WM Teeuwisse… - 2010 - repository.ubn.ru.nl
SETTING: Cochlear implant (CI)/tertiary referral center. SUBJECTS: Twenty-five patients
implanted with an Advanced Bionics HiRes90K HiFocus1J CI. STUDY DESIGN/MAIN …

Cochlear Coordinates in Regard to Cochlear Implantation: A Clinically Individually Applicable 3 Dimensional CT-Based Method

BM Verbist, RMS Joemai, JJ Briaire… - Otology & …, 2010 - journals.lww.com
Setting: Cochlear implant (CI)/tertiary referral center. Subjects: Twenty-five patients
implanted with an Advanced Bionics HiRes90K HiFocus1J CI. Study Design/Main Outcome …

[PDF][PDF] Cochlear Coordinates in Regard to Cochlear Implantation: a Clinically Individually Applicable 3-dimensional CT-based Method

BM Verbist, RMS Joemai, JJ Briaire… - … imaging in the … - scholarlypublications …
Study Design/main outcome measures: A 3-dimensional cylindrical coordinate system is
introduced using the basal turn of the cochlea as the x, y-plane and the center of the …

Cochlear coordinates in regard to cochlear implantation: a clinically individually applicable 3 dimensional CT-based method

BM Verbist, RMS Joemai, JJ Briaire… - … publication of the …, 2010 - pubmed.ncbi.nlm.nih.gov
Setting Cochlear implant (CI)/tertiary referral center. Subjects Twenty-five patients implanted
with an Advanced Bionics HiRes90K HiFocus1J CI. STUDY DESIGN/MAIN OUTCOME …

[PDF][PDF] Cochlear Coordinates in Regard to Cochlear Implantation: A Clinically Individually Applicable 3 Dimensional CT-Based Method

BM Verbist, RMS Joemai, JJ Briaire… - Otology & …, 2010 - academia.edu
Study Design/Main Outcome Measures: A 3-dimensional cylindrical coordinate system is
introduced using the basal turn of the cochlea as the x and y planes and the center of the …

[PDF][PDF] Cochlear Coordinates in Regard to Cochlear Implantation: a Clinically Individually Applicable 3-dimensional CT-based Method

BM Verbist, RMS Joemai, JJ Briaire, WM Teeuwisse… - scholar.archive.org
Study Design/main outcome measures: A 3-dimensional cylindrical coordinate system is
introduced using the basal turn of the cochlea as the x, y-plane and the center of the …

[PDF][PDF] Cochlear Coordinates in Regard to Cochlear Implantation: a Clinically Individually Applicable 3-dimensional CT-based Method

BM Verbist, RMS Joemai, JJ Briaire, WM Teeuwisse… - scholarlypublications …
Study Design/main outcome measures: A 3-dimensional cylindrical coordinate system is
introduced using the basal turn of the cochlea as the x, y-plane and the center of the …