A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI
DE Bohning, S Denslow, PA Bohning, JA Walker… - Clinical …, 2003 - Elsevier
… /software system for MR-guided TMS coil positioning in interleaved TMS/fMRI studies. …
physiology laboratory applications of TMS, they are not ideal for interleaved TMS/fMRI. Since the …
physiology laboratory applications of TMS, they are not ideal for interleaved TMS/fMRI. Since the …
An increased precision comparison of TMS-induced motor cortex BOLD fMRI response for image-guided versus function-guided coil placement
S Denslow, DE Bohning, PA Bohning… - Cognitive and …, 2005 - journals.lww.com
… determination of TMS coil location, we performed interleaved TMS and fMRI to determine …
fMRI response location and level for function-guided TMS coil positioning versus image-guided …
fMRI response location and level for function-guided TMS coil positioning versus image-guided …
Improved SNR for combined TMS-fMRI: a support device for commercially available body array coil
WT Wang, B Xu, JA Butman - Journal of neuroscience methods, 2017 - Elsevier
… That is, the lengthened TR was to interleave between TMS pulse application and MR image
… A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI …
… A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI …
[PDF][PDF] Interleaving TMS with functional MRI: now that it is technically feasible how should it be used?
HR Siebner, L Lee, S Bestmann - Clinical neurophysiology, 2003 - embiolab.ifac.cnr.it
… A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI.
Clin Neurophysiol 2003;114:2210–9. Catafau AM, Perez V, Gironell A, Martin JC, Kulisevsky J, …
Clin Neurophysiol 2003;114:2210–9. Catafau AM, Perez V, Gironell A, Martin JC, Kulisevsky J, …
Cortical and subcortical brain effects of transcranial magnetic stimulation (TMS)-induced movement: an interleaved TMS/functional magnetic resonance imaging study
S Denslow, M Lomarev, MS George, DE Bohning - Biological psychiatry, 2005 - Elsevier
… Accordingly, we used interleaved TMS/fMRI in a large study to … The TMS coil was adjusted
to a scalp position for stimulation of the left motor cortex determined by pulsing the TMS coil at …
to a scalp position for stimulation of the left motor cortex determined by pulsing the TMS coil at …
Functional magnetic resonance imaging and transcranial magnetic stimulation: effects of motor imagery, movement and coil orientation
… Our results suggest that the discrepancy between fMRI and TMS motor maps may be largely
due to … Others simultaneously recorded cortical activity by interleaving TMS and fMRI thus …
due to … Others simultaneously recorded cortical activity by interleaving TMS and fMRI thus …
Application and Progress of Real-time Interleaved Transcranial Magnetic Stimulation Functional Magnetic Resonance Imaging
MA Yi-qi, XIE Ruo-xi, Z Zhong, MA Dan… - Journal of Sichuan …, 2020 - jsu-mse.com
… In this review, we elaborates the advances, limitations and future expectations of real-time
interleaved TMS-fMRI. From … A TMS coil positioning/holding system for MR image-guided TMS …
interleaved TMS-fMRI. From … A TMS coil positioning/holding system for MR image-guided TMS …
[HTML][HTML] Reducing image artefacts in concurrent TMS/fMRI by passive shimming
A Bungert, CD Chambers, M Phillips, CJ Evans - Neuroimage, 2012 - Elsevier
… In this work, we demonstrate that the detrimental susceptibility effects of the TMS-coil on
MR image quality can be substantially reduced using a thin distribution of weakly-ferromagnetic …
MR image quality can be substantially reduced using a thin distribution of weakly-ferromagnetic …
Implementation of a TMS-fMRI system: A primer
G Alamian, R Ge, A Humaira, E Gregory, EL MacMillan… - bioRxiv, 2021 - biorxiv.org
… in the installation of the concurrent TMS-fMRI setup could potential artefacts arise from… TMS
was not in the MRI room, when the TMS coil was in the MR-room but OFF, when the TMS coil …
was not in the MRI room, when the TMS coil was in the MR-room but OFF, when the TMS coil …
Changes in cerebral activations during movement execution and imagery after parietal cortex TMS interleaved with 3T MRI
PM de Vries, BM de Jong, DE Bohning, JA Walker… - Brain research, 2009 - Elsevier
… functional magnetic resonance imaging (fMRI) with interleaved TMS. They either executed
or … A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI …
or … A TMS coil positioning/holding system for MR image-guided TMS interleaved with fMRI …