Doses in organs at risk during head and neck radiotherapy using IMRT and 3D-CRT

M Peszynska-Piorun, J Malicki… - Radiology and oncology, 2012 - sciendo.com
… Although IMRT allows a better dose conformity in PTV, there is … less dose to OAR is delivered.
Therefore, the aim of the study was to compare IMRT to 3D-CRT treatment in terms of dose

[HTML][HTML] Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT

DT Tai, LT Oanh, PH Phuong, A Sulieman… - Saudi Journal of …, 2022 - Elsevier
… The 3D-CRT and JO-IMRT plans had average doses to the … , for the 3D-CRT and JO-IMRT
designs, the average doses to … For the 3D-CRT and JO-IMRT designs, the CI and HI were …

[HTML][HTML] Toxicity profile of IMRT vs. 3D-CRT in head and neck cancer: A retrospective study

G Ghosh, R Tallari, A Malviya - Journal of clinical and diagnostic …, 2016 - ncbi.nlm.nih.gov
… aim of delivering cancericidal dose to tumour while delivering miminum dose to surrounding
normal tissues. As compared to conventional radiotherapy, IMRT/3D-CRT technique offers …

Three-dimensional conformal radiotherapy (3D-CRT) versus intensity modulated radiation therapy (IMRT) in squamous cell carcinoma of the head and neck: a …

T Gupta, JP Agarwal, S Jain, R Phurailatpam… - Radiotherapy and …, 2012 - Elsevier
… was to achieve a mean dose ⩽26 Gy for the contralateral parotid gland and limit the
maximum spinal cord dose to <45 Gy. The total doses used in 3D-CRT and IMRT were deemed …

Dose variations in tumor volumes and organs at risk during IMRT for head‐and‐neck cancer

M Beltran, M Ramos, JJ Rovira… - Journal of Applied …, 2012 - Wiley Online Library
… cancer (HNC) patients treated with radiotherapy suffer … dose changes over target volumes
and organs at risk during … of OARs than conventional 3D CRT, some of them at high doses. In …

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

DK Ismael, FF Hassan - Hospital Practices and Research, 2020 - jhpr.ir
3D-CRT and IMRT were used to produce the maximum dose of target volume coverage and
minimum dose … Data analysis was performed using the available statistical package of SPSS …

[HTML][HTML] … radiotherapy and intensity modulated radiotherapy with or without simultaneous integrated boost during concurrent chemoradiation for locally advanced head …

MT Spiotto, RR Weichselbaum - Plos one, 2014 - journals.plos.org
using 3D-CRT, IMRTseq or IMRT+SIB. Between 1993 and 2012, 379 patients with non-metastatic
Stage III-IV head and neckradiotherapy (3D-CRT) where increasing radiation doses

[PDF][PDF] Evaluation of Radiation Doses Received by Organs at Risk in 3D Conformal and Intensity Modulated Radiotherapy for Head and Neck Cancer

HA Hassan, KA Faraj, ZY Saeed - … of Zankoy Sulaimani-Part A, 2019 - researchgate.net
… the doses delivered to the critical structures located close to the target volume during head
and neck radiotherapy by 3D-CRT and IMRT … and hypopharynx", Head Neck. Vol. 12, No. …

… comparison between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in the treatment of different stages of …

MS Ibrahim, EM Attalla, M El Naggar… - … of Radiotherapy in …, 2019 - cambridge.org
… The dose delivered to PTV1 and PTV2 for 3D-CRT and 7F-IMRT are statistically similar, …
9F-IMRT is significantly better than 3D-CRT. For organs at risk (OARs), the delivered dose is …

[HTML][HTML] … modulated radiation therapy versus three-dimensional conformal radiotherapy in head and neck squamous cell carcinoma: long-term and mature outcomes of …

T Gupta, S Sinha, S Ghosh-Laskar, A Budrukkar… - Radiation …, 2020 - Springer
… Patients were treated with 6MV photons to a total dose of 70Gy/35 fractions over 7 weeks
(3D-CRT) or 66Gy/30 fractions over 6 weeks (IMRT). A sample size of 60 patients was …