Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

H Palmans, F Verhaegen - 1995 - osti.gov
… world created by the treatment planning software. Current high-… issues regarding dynamic
conformal therapy have not been … to plan and deliver beam intensity modulated radiotherapy

[PDF][PDF] in combination with IMRT and 3D-CRT: Monte Carlo-based planning

J Seuntjens - GGGGG GGG aLLLL - collectionscanada.gc.ca
… For dynamic dclivery in IMRT plans, the leaf sequence files … first commercial IMRT Monte
Carlo treatment planning system at … response and wall correction factors for ionization chambers

Development of a Monte Carlo simulation method for the evaluation of dose distribution calculations of radiotherapy treatment planning systems

FCP Du Plessis - 1999 - scholar.ufs.ac.za
… Sampling of interaction dynamic variables … scored directly below an ion chamber to act
as a source for open and wedged x-ray beams with different jaw settings (field sizes) and at an …

Clinical implementation of full Monte Carlo dose calculation in proton beam therapy

H Paganetti, H Jiang, K Parodi… - Physics in Medicine …, 2008 - iopscience.iop.org
… to support routine treatment planning and delivery. The … mm is used while for the ionization
chamber we use 0.1 mm to … P 2001a Monte Carlo simulation of a dynamic MLC based on a …

Dosimetric evaluation of a dedicated stereotactic linear accelerator using measurement and Monte Carlo simulation

M Heydarian, K Asnaashari, M Allahverdi… - Medical …, 2008 - Wiley Online Library
Ionization chamber dosimetry results for a phantom IMRT … and leaf traveling during beam
delivery in dynamic mode. De … -RT treatment planning system on a cylindrical IMRT phantom …

[PDF][PDF] Monte Carlo modeling of Helical Tomotherapy and evaluation of its treatment planning system

YL Zhao - 2008 - era.library.ualberta.ca
… point with an ion chamber and one plane with film measurement, … In the dynamic MLC mode
of IMRT delivery, the opposing … distribution is compared with an absolute ionization chamber

Monte Carlo simulation for MLC-based intensity-modulated radiotherapy

T Pawlicki, CMC Ma - Medical Dosimetry, 2001 - Elsevier
… distal to the flattening filter and proximal to the ion chamber. … of Monte Carlo to IMRT, namely
IMRT treatment plan … the Corvus TM inverse treatment planning system (Nomos Corporation…

Dosimetric comparison of iPlanⓇ Pencil Beam (PB) and Monte Carlo (MC) algorithms in stereotactic radiosurgery/radiotherapy (SRS/SRT) plans of intracranial …

SV Menon, R Paramu, S Bhasi, Z Gopalakrishnan… - Medical …, 2020 - Elsevier
… of the dose calculation depends on the treatment planning … ) of BrainLAB Ⓡ iPlan Ⓡ treatment
planning system (TPS), each … ionization chamber as obtained from the TPS was compared

[PDF][PDF] Measurement issues in commissioning and benchmarking of Monte Carlo treatment planning systems

J Seuntjens - … : Monte Carlo and Image-Guided Radiation Therapy, 2006 - aapm.org
ionization chambers: based on Monte Carlo calculations and … Comparison of measured and
calculated in-air profile for 40 … proper OAR dose calculations ALSO for non-IMRT planning – …

Clinical implementation of a Monte Carlo based treatment plan QA platform for validation of Cyberknife and Tomotherapy treatments

N Reynaert, B Demol, M Charoy, S Bouchoucha… - Physica Medica, 2016 - Elsevier
Carlo algorithm of the treatment planning system. For some … system was used at the
University of Ghent to validate IMRT … Recent treatment options such as the dynamic jaws and …