First on-site true gamma-ray imaging-spectroscopy of contamination near Fukushima plant

D Tomono, T Mizumoto, A Takada, S Komura… - Scientific Reports, 2017 - nature.com
… to estimate potential health effects to the human body. The 1-… with a 10 cm × 10 cm × 16 cm
gas volume, based on the 30-cm-… We detected 662-keV gammas from the point source with a …

Estimation of the radiation dose from radiotherapy for skin haemangiomas in childhood: the ICTA software for epidemiology

A Shamsaldin, M Lundell, I Diallo, L Ligot… - Physics in Medicine …, 2000 - iopscience.iop.org
gamma irradiation was considered in our model for dose … ) is very good close to the source
(up to 10 cm), but decreases … negligible bremsstrahlung doses for points located at distances …

Monte Carlo and TLD dosimetry of an high dose‐rate brachytherapy source

P Karaiskos, A Angelopoulos, L Sakelliou… - Medical …, 1998 - Wiley Online Library
… when the absorbed dose is calculated near body edges. On the … the source closest to the
origin was found. In this way, the … of the source, derived from our code at radial distance r 10 cm

An electronically collimated gamma camera for single photon emission computed tomography. Part I: Theoretical considerations and design criteria

M Singh - Medical physics, 1983 - Wiley Online Library
… (1)-(4), a point source located 10 cm from det 1 will produce … The sensitivity gain is higher
for points located closer to the … the body has been studied, and a gamma camera based upon …

A new miniature x‐ray device for interstitial radiosurgery: dosimetry

J Beatty, PJ Biggs, K Gall, P Okunieff, FS Pardo… - Medical …, 1996 - Wiley Online Library
… "Co sources collimated to the same point (Leksell Gamma Knife … is symmetrically located l
cm from the tip of the source and … between the source and the detector set to 10 cm, the dead …

[引用][C] The latest data on effective dose (equivalent) for hot particles on the skin

XG Xu - Health Phys, 2005

Multisphere neutron spectra measurements near a high energy medical accelerator

KG Veinot, NE Hertel, KW Brooks, JE Sweezy - Health physics, 1998 - journals.lww.com
… a "Co source, since the response of these TLDs to gamma … was found by using the known
dose equivalent rate at point 11… the conditions of this work (10 cm X 10 cm field size at 25 MV). …

Design and development of a high-energy gamma camera for use with NSECT imaging: feasibility for breast imaging

AC Sharma, GD Tourassi, AJ Kapadia… - … on Nuclear Science, 2007 - ieeexplore.ieee.org
… with elemental nuclei within the body. The characteristic … the number of gammas as one
located 10 cm away, the solid … In conclusion, the design of a near field, high energy, gamma

Personnel exposure during gamma endovascular brachytherapy

S Balter, M Oetgen, A Hill, J Dalton, A Sacher… - Health …, 2000 - journals.lww.com
… Catheter-based delivery of gamma radiation has emerged as … They were usually placed near
the door and window to allow … the source and the monitored points includes about 10 cm of …

External Doses to Terrestrial Gamma Rays on the Snow Cover

K Saito - Radiation protection dosimetry, 1991 - academic.oup.com
… cover at a water equivalent of 30 cm was found to be smailer … First, we define K(h,w) as the
air kerma per unit source … The doses for organs located near the surface of the body such as …