Professional hygiene care, adjustments and complications of mandibular implant-retained overdentures: a three-year retrospective study
ACL den Dunnen, AP Slagter, C de Baat… - The Journal of prosthetic …, 1997 - Elsevier
… The follow-up period after insertion of the overdentures was … implant loss mostly occurs in
early stages of loading. 16, 17, 18 … -clip attachment, or in other words, absence of direct contact …
early stages of loading. 16, 17, 18 … -clip attachment, or in other words, absence of direct contact …
The effect of varying implant position in immediately loaded implant-supported mandibular overdentures
MA Shaarawy, EM Aboelross - Journal of Oral …, 2013 - meridian.allenpress.com
… University, Egypt, over a period of 1 year were screened for … results for immediate loading
of overdentures retained by … into the denture base by the direct pickup as the denture is in …
of overdentures retained by … into the denture base by the direct pickup as the denture is in …
Retentive Properties of Two Stud Attachments with Polyetherketoneketone or Nylon Insert in Mandibular Implant Overdentures.
JW Choi, BH Yun, CM Jeong… - International Journal of …, 2018 - search.ebscohost.com
… The retention of implant-retained overdentures particularly has a direct relation to the …
Retention of ERA direct overdenture attachments before and after fatigue loading. Int J Prosthodont …
Retention of ERA direct overdenture attachments before and after fatigue loading. Int J Prosthodont …
Loading protocols for implant-supported overdentures in the edentulous jaw: a systematic review and meta-analysis.
M Schimmel, M Srinivasan… - … Journal of Oral & …, 2014 - search.ebscohost.com
… loaded singleimplant retained overdentures after verifying … this adaptive period with
implant-supported overdentures,52 … in case the attachments are engaged by means of direct polym…
implant-supported overdentures,52 … in case the attachments are engaged by means of direct polym…
Effects of Implant Angulations and Attachment Configurations on the Retentive Forces of Locator Attachment–Retained Overdentures.
… implants may stand alone and retain the overdenture with stud attachments.The choice of …
Retention of ERA direct overdenture attachments before and after fatigue loading. Int J …
Retention of ERA direct overdenture attachments before and after fatigue loading. Int J …
[PDF][PDF] Masticatory performance of complete denture wearers before and after the provision of mandibular implant overdentures: a systematic review.
I Tsolianos - 2019 - ikee.lib.auth.gr
… In most of them, overdentures were assisted by two implants and retention was provided
by unsplinted attachments. Conclusion: Masticatory performance may be improved when …
by unsplinted attachments. Conclusion: Masticatory performance may be improved when …
[HTML][HTML] The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems
S Monteiro, P Barreiros, J Mendes, C Aroso, AS Silva… - Biomedicines, 2023 - mdpi.com
… of conventional complete denture therapy is directly affected by … , since each has its own
mechanical properties and load … period of 12 months followed by simulated cycles of function. …
mechanical properties and load … period of 12 months followed by simulated cycles of function. …
Wear of matrix overdenture attachments after one to eight years of clinical use
O Fromentin, C Lassauzay, S Abi Nader, J Feine… - The Journal of prosthetic …, 2012 - Elsevier
… , the loading period was rather short for any retention loss to … data concerning maintenance
were collected directly from the … a high level of retention of their overdenture attachment at the …
were collected directly from the … a high level of retention of their overdenture attachment at the …
Evaluation of Fatigue Resistance of Esthetic and Metal Clasps for Removable Partial Denture: An In Vitro study
M Rajachitra - 2020 - repository-tnmgrmu.ac.in
… Primary retention for the removable partial denture is … its retention even over a simulated
5-year period, with lower … study fatigue was observed after 24 months of cyclic loading …
5-year period, with lower … study fatigue was observed after 24 months of cyclic loading …
Mandibular overdentures retained by two mini‐implants: a seven‐year retention and satisfaction study
A Catalán, A Martínez, F Marchesani… - Journal of …, 2016 - Wiley Online Library
… been machined with matching denture attachments (Intra lock… a period of 7 years the following
features: (a) retention of … -implants and loaded within 15 to 21 days after placing the mini-…
features: (a) retention of … -implants and loaded within 15 to 21 days after placing the mini-…