[PDF][PDF] SOLVING OPEN ACCESS TRANSMISSION AND SECURITY ANALYSIS PROBLEMS WITH THE SHORT-CIRCUIT CURRENTS METHOD 十

SC Savulescu - 2002 - Citeseer
This paper describes two applications of Paul Dimo's short-circuit currents method based
Nodal Analysis--real-time external network modeling in an energy management system by …

Voltage stability assessment for real-time operation

RB Prada, EGC Palomino, JOR Dos Santos… - IEE Proceedings …, 2002 - IET
Network voltage stability is represented by nodal conditions associated with the maximum
active and reactive power flow that can be transmitted from generators to loads. An …

[PDF][PDF] Integrated security analysis

PW Sauer, K Tomsovic, J Dagle… - Final Report …, 2004 - eta-publications.lbl.gov
As economic pressures result in greatly expanded utilization of facilities, the issue of power
system security analysis is key to reliable operation at maximum efficiency. Security analysis …

Design and implementation of real-time voltage stability analysis at CAISO

M Varghese, D Salem-Natarajan… - 2008 IEEE Power …, 2008 - ieeexplore.ieee.org
The Real-Time Voltage Stability Analysis (RTVSA) project is slated to be a part of the suite of
computational tools needed for congestion management in the California ISO (CAISO). This …

A robust quasi-direct continuous power-flow analysis using two-bus equivalents for voltage stability analysis of radial distribution systems

MM Aly, M Abdel-Akher - Electrical Engineering, 2018 - Springer
This paper presents a new and fast method to trace the P–V curves in voltage stability of
radial distribution power systems. The proposed method is suitable for ill-condition problems …

Turbo-SPICE with latency insertion method (LIM)

Z Deng, JE Schutt-Ainé - IEEE 14th Topical Meeting on …, 2005 - ieeexplore.ieee.org
In this work, the latency insertion method (LIM) for the time-domain simulation of networks is
incorporated into SPICE3f5 for the faster simulation of power distribution networks. This …

Equivalents for security analysis of power systems

SC Savulescu - IEEE Transactions on Power Apparatus and …, 1981 - ieeexplore.ieee.org
This paper describes a procedure to generate an adaptive Dimo equivalent. Fictitious nodes
aggregate buses belonging to the same class of REI equivalence. As a result, an equivalent …

Fast nodal assessment of static voltage stability including contingency analysis

RB Prada, JOR Dos Santos - Electric power systems research, 1999 - Elsevier
A nodal static voltage stability evaluation analytical tool for electric power systems is
presented. The method is based on a straightforward physical characterization of the voltage …

Passivity enforcement using an infeasible-interior-point primal-dual method

B Porkar, M Vakilian, R Iravani… - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
Application of the network equivalent concept for external system representation in
electromagnetic transient studies is well known. However, the challenge in application of an …

Voltage stability assessment using equivalent nodal analysis

DHA Lee - IEEE transactions on Power Systems, 2015 - ieeexplore.ieee.org
This paper presents a simple method for voltage stability assessment by reducing the bus