High‐power short‐duration versus standard radiofrequency ablation: insights on lesion metrics
F Bourier, J Duchateau, K Vlachos… - Journal of …, 2018 - Wiley Online Library
Introduction Radiofrequency (RF) lesion metrics are influenced by underlying parameters
like RF power, duration, and contact force (CF), and utilization of lesion metric indices …
like RF power, duration, and contact force (CF), and utilization of lesion metric indices …
[HTML][HTML] Effect of baseline impedance in radiofrequency delivery on lesion characteristics and the relationship between impedance and steam pops
L Qu, M Guo, M Sun, R Wang, N Zhang… - Frontiers in …, 2022 - frontiersin.org
Objective: To explore the effects of baseline impedance (R) and power (P) on
radiofrequency ablation lesion characteristics and their correlation with steam pops through …
radiofrequency ablation lesion characteristics and their correlation with steam pops through …
[PDF][PDF] Radiofrequency ablation: Four decades later, still optimizing lesion characterization
A Enriquez, S Kattel - Authorea Preprints, 2022 - techrxiv.org
Radiofrequency Ablation: Four Decades Later, Still Optimizing Lesion Characterization Alan
D. Enriquez, MD 1, 2; Sharma Kattel MD, PhD11Section of Cardiovascular Medicine, Yale …
D. Enriquez, MD 1, 2; Sharma Kattel MD, PhD11Section of Cardiovascular Medicine, Yale …
射频消融前后CK-MB, hs-CRP 的测定及意义
韦德宇, 丁晓梅, 范西真, 安春生, 苏浩 - 安徽医药, 2011 - cqvip.com
目的通过观察使用温控大头电极射频消融术(RFCA) 前后超敏C-反应蛋白(hs-CRP)
和肌酸激酶同工酶MB (CK-MB) 的变化, 分析温控大头电极RFCA 对心肌组织的损伤 …
和肌酸激酶同工酶MB (CK-MB) 的变化, 分析温控大头电极RFCA 对心肌组织的损伤 …
Epicardial radiofrequency ablation of ventricular myocardium: factors affecting lesion formation and damage to adjacent structures
G Fenelon, KP Pereira, AAV de Paola - Journal of interventional cardiac …, 2006 - Springer
We evaluated the factors affecting epicardial radiofrequency (RF) lesion formation in normal
ventricular myocardium. In 16 dogs, a minithoracotomy was made and a sheath was placed …
ventricular myocardium. In 16 dogs, a minithoracotomy was made and a sheath was placed …
快速性心律失常的射频消融治疗
杨新春, 胡大一 - 中国医刊, 1999 - cqvip.com
射频电流导管消融是以射频电流为能源, 利用导管技术, 通过消融心脏内特殊传导组织以达到
治疗心律失常的目的. 目前, 临床上使用的射频电流的频率范围为300~ 750kHz …
治疗心律失常的目的. 目前, 临床上使用的射频电流的频率范围为300~ 750kHz …
[HTML][HTML] Efficacy of a cooled bipolar epicardial radiofrequency ablation probe for creating transmural myocardial lesions
MA Wood, AL Ellenbogen, V Pathak… - The Journal of Thoracic …, 2010 - Elsevier
OBJECTIVE: Creation of transmural myocardial lesions with epicardial surgical devices to
treat atrial fibrillation is difficult. A new cooled bipolar radiofrequency ablation probe was …
treat atrial fibrillation is difficult. A new cooled bipolar radiofrequency ablation probe was …
Temperature-controlled radiofrequency catheter ablation with a 10-mm tip electrode creates larger lesions without charring in the porcine heart
OG Anfinsen, H Aass, E Kongsgaard, A Foerster… - Journal of interventional …, 1999 - Springer
Background: Radiofrequency catheter ablation of atrial flutter, atrial fibrillation or ventricular
tachycardia may be favoured by large lesions. We compared lesions created in unipolar …
tachycardia may be favoured by large lesions. We compared lesions created in unipolar …