Metal-on-metal bearings: the evidence so far
FS Haddad, RR Thakrar, AJ Hart… - The Journal of Bone …, 2011 - boneandjoint.org.uk
Lately, concerns have arisen following the use of large metal-on-metal bearings in hip
replacements owing to reports of catastrophic soft-tissue reactions resulting in implant failure …
replacements owing to reports of catastrophic soft-tissue reactions resulting in implant failure …
Metal on metal bearings in hip arthroplasty
HC Amstutz, P Grigoris - Clinical Orthopaedics and Related …, 1996 - journals.lww.com
Periprosthetic osteolysis caused by wear debris released from the bearing surface of
polyethylene components is the major problem in contemporary hip arthroplasty. Several …
polyethylene components is the major problem in contemporary hip arthroplasty. Several …
Metal-on-metal total hip arthroplasty: the concerns
SJ MacDonald - Clinical Orthopaedics and Related Research®, 2004 - journals.lww.com
The metal-on-metal bearing couple is having a resurgence in clinical applications seen in
total hip and hip resurfacing technologies. The most noteworthy advantage of a metal-on …
total hip and hip resurfacing technologies. The most noteworthy advantage of a metal-on …
Metal on metal total hip replacement workshop consensus document
HC Amstutz, P Campbell, H McKellop… - Clinical Orthopaedics …, 1996 - journals.lww.com
The objective of this workshop was to provide a forum to discuss the reintroduction of metal
on metal bearings for clinical use in total hip arthroplasty. Approximately 100 researchers …
on metal bearings for clinical use in total hip arthroplasty. Approximately 100 researchers …
Metal-on-metal bearing surfaces
Metalonmetal bearing couples remain a popular option in total hip arthroplasty and are
the only currently available option for surface replacement arthroplasty. In general, the …
the only currently available option for surface replacement arthroplasty. In general, the …
Failed metal-on-metal hip arthroplasties: a spectrum of clinical presentations and operative findings
JA Browne, CD Bechtold, DJ Berry… - … and Related Research®, 2010 - Springer
Background A number of recent reports have described novel failure mechanisms of metal-
on-metal bearings in total and resurfacing hip arthroplasty. Hip arthroplasties with metal-on …
on-metal bearings in total and resurfacing hip arthroplasty. Hip arthroplasties with metal-on …
Metal-on-metal hip arthroplasty: does early clinical outcome justify the chance of an adverse local tissue reaction?
CA Engh Jr, H Ho, CA Engh - Clinical Orthopaedics and Related …, 2010 - journals.lww.com
Larger diameter metal-on-metal (MOM) bearing hips offer the possibility of low wear and
reduced risk of dislocation. We reviewed the first 126 patients (131 hips) who had a large …
reduced risk of dislocation. We reviewed the first 126 patients (131 hips) who had a large …
A multinational assessment of metal-on-metal bearings in hip replacement
There is emerging evidence that many metal-on-metal (MoM) bearings, when used with
large femoral heads in conventional hip replacement and some resurfacing prostheses, are …
large femoral heads in conventional hip replacement and some resurfacing prostheses, are …
[HTML][HTML] European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing
F Hannemann, A Hartmann, J Schmitt, J Lützner… - … & Traumatology: Surgery …, 2013 - Elsevier
INTRODUCTION: There is an ongoing debate about the optimal use of metal-on-metal
(MoM) bearings in total hip replacement, since there are uncertainties about local and …
(MoM) bearings in total hip replacement, since there are uncertainties about local and …
Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear
Early failure associated with adverse reactions to metal debris is an emerging problem after
hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 …
hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 …