Four‐dimensional (4D) PET/CT imaging of the thorax: 4D PET/CT
SA Nehmeh, YE Erdi, T Pan, A Pevsner… - Medical …, 2004 - Wiley Online Library
… of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of
… address the problem of respiration motion in PET/CT imaging. The respiratory motion of four …
… address the problem of respiration motion in PET/CT imaging. The respiratory motion of four …
Generation of 4-dimensional CT images based on 4-dimensional PET–derived motion fields
HJ Fayad, F Lamare, CC Le Rest… - Journal of Nuclear …, 2013 - Soc Nuclear Med
… sufficient statistics for the accurate derivation of 4D CT series from the 4D NAC PET images.
… of producing a 4D CT series from the corresponding NAC 4D PET images and a single …
… of producing a 4D CT series from the corresponding NAC 4D PET images and a single …
Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images
SJ Park, D Ionascu, J Killoran, M Mamede… - Physics in Medicine …, 2008 - iopscience.iop.org
… profiles from (a) 3D-PET/3D-CT and (b) 4D-PET/4DCT images of the 0.5 mL sphere (10 mm
… profiles from (a) 3D-PET/3D-CT and (b) 4D-PET/4DCT images of the 16 mL sphere (31 mm …
… profiles from (a) 3D-PET/3D-CT and (b) 4D-PET/4DCT images of the 16 mL sphere (31 mm …
Clinical utility of 4D FDG-PET/CT scans in radiation treatment planning
M Aristophanous, RI Berbeco, JH Killoran… - International Journal of …, 2012 - Elsevier
… the 4D PET scan with the 4D CT … imaging by use of fluoroscopy or 4D CT. If a large range
of motion of the tumor is observed, a 4D PET scan could be prescribed in situations where PET …
of motion of the tumor is observed, a 4D PET scan could be prescribed in situations where PET …
Attenuation correction of PET images with respiration-averaged CT images in PET/CT
… 4D CT data to obtain ACT for AC of the PET … CT data for quantification of the PET data. On
the basis of our experience with 4D PET/CT studies (18–20), most tumors examined by PET …
the basis of our experience with 4D PET/CT studies (18–20), most tumors examined by PET …
Improvement of the cine‐CT based 4D‐CT imaging
T Pan, X Sun, D Luo - Medical physics, 2007 - Wiley Online Library
… images may not require a respiratory signal. We proposed the application of MIP CT images
from 4D-CT … sorting the cine CT images to 4D-CT images, MIP and AVG CT images, please …
from 4D-CT … sorting the cine CT images to 4D-CT images, MIP and AVG CT images, please …
Quantitation of respiratory motion during 4D‐PET/CT acquisition
SA Nehmeh, YE Erdi, T Pan, E Yorke… - Medical …, 2004 - Wiley Online Library
… the CT and PET image sets, especially in the thorax, is a major problem for diagnostic
accuracy. Because CT images are used to correct for attenuation in PET images, a … the 4D-PET/CT …
accuracy. Because CT images are used to correct for attenuation in PET images, a … the 4D-PET/CT …
Attenuation correction of four dimensional (4D) PET using phase-correlated 4D-computed tomography
F Pönisch, C Richter, U Just… - Physics in Medicine & …, 2008 - iopscience.iop.org
… PET images has been analyzed. The results demonstrate the feasibility of such a procedure,
and we therefore recommend that 4D-PET data should be reconstructed using 4D-CT data, …
and we therefore recommend that 4D-PET data should be reconstructed using 4D-CT data, …
Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans
JH Killoran, VH Gerbaudo, M Mamede… - Journal of Applied …, 2011 - Wiley Online Library
… The purpose of this study is to evaluate the performance of 4D PET imaging, and examine
the choice of attenuation correction method using a phantom designed to represent the lung–…
the choice of attenuation correction method using a phantom designed to represent the lung–…
Usefulness of four dimensional (4D) PET/CT imaging in the evaluation of thoracic lesions and in radiotherapy planning: Review of the literature
A Sindoni, F Minutoli, A Pontoriero, G Iatì, S Baldari… - Lung Cancer, 2016 - Elsevier
… a significant impact on 4D-PET images. The consistency of … PET/CT images, and their RB
method have improved 4D PET… image sets via automatic co-registrations of 4D CT-FDG PET …
method have improved 4D PET… image sets via automatic co-registrations of 4D CT-FDG PET …
相关搜索
- respiratory motion artifacts in pet imaging
- attenuation correction of pet images
- intelligent 4d ct sequence scanning
- pet images effect of respiratory gating
- dual respiratory pet imaging
- four dimensional 4d pet ct imaging
- target size pet ct images
- fdg pet ct imaging tumor volumes
- dual modality pet ct imaging
- indications and findings pet ct imaging
- pet mr hybrid imaging
- respiratory gated 4d pet
- pet emission images
- pet ct for radiotherapy planning
- internal target volume 4d pet
- pet imaging of lung cancer