A nonlinear biphasic fiber-reinforced porohyperviscoelastic model of articular cartilage incorporating fiber reorientation and dispersion

A Seifzadeh, J Wang, DCD Oguamanam, M Papini - 2011 - asmedigitalcollection.asme.org
A Seifzadeh, J Wang, DCD Oguamanam, M Papini
2011asmedigitalcollection.asme.org
A nonlinear biphasic fiber-reinforced porohyperviscoelastic (BFPHVE) model of articular
cartilage incorporating fiber reorientation effects during applied load was used to predict the
response of ovine articular cartilage at relatively high strains (20%). The constitutive material
parameters were determined using a coupled finite element-optimization algorithm that
utilized stress relaxation indentation tests at relatively high strains. The proposed model
incorporates the strain-hardening, tension-compression, permeability, and finite deformation …
A nonlinear biphasic fiber-reinforced porohyperviscoelastic (BFPHVE) model of articular cartilage incorporating fiber reorientation effects during applied load was used to predict the response of ovine articular cartilage at relatively high strains (20%). The constitutive material parameters were determined using a coupled finite element-optimization algorithm that utilized stress relaxation indentation tests at relatively high strains. The proposed model incorporates the strain-hardening, tension-compression, permeability, and finite deformation nonlinearities that inherently exist in cartilage, and accounts for effects associated with fiber dispersion and reorientation and intrinsic viscoelasticity at relatively high strains. A new optimization cost function was used to overcome problems associated with large peak-to-peak differences between the predicted finite element and experimental loads that were due to the large strain levels utilized in the experiments. The optimized material parameters were found to be insensitive to the initial guesses. Using experimental data from the literature, the model was also able to predict both the lateral displacement and reaction force in unconfined compression, and the reaction force in an indentation test with a single set of material parameters. Finally, it was demonstrated that neglecting the effects of fiber reorientation and dispersion resulted in poorer agreement with experiments than when they were considered. There was an indication that the proposed BFPHVE model, which includes the intrinsic viscoelasticity of the nonfibrillar matrix (proteoglycan), might be used to model the behavior of cartilage up to relatively high strains (20%). The maximum percentage error between the indentation force predicted by the FE model using the optimized material parameters and that measured experimentally was 3%.
The American Society of Mechanical Engineers
以上显示的是最相近的搜索结果。 查看全部搜索结果