Accuracy of digital and conventional implant‐level impression techniques for maxillary full‐arch screw‐retained prosthesis: A crossover randomized trial

AG Jasim, MG Abo Elezz, GY Altonbary… - … Implant Dentistry and …, 2024 - Wiley Online Library
AG Jasim, MG Abo Elezz, GY Altonbary, MA Elsyad
Clinical Implant Dentistry and Related Research, 2024Wiley Online Library
Objectives This study aimed to compare the accuracy of implant‐level conventional and
digital impressions for atrophied maxillary ridges. Materials and Methods Twelve
participants with atrophied edentulous maxillary ridges received six implants. Six months
later and after soft tissue maturation around healing abutments, a control cast was
constructed using the final passive restoration for each patient. Two types of implant‐level
impression techniques were carried out for each patient:(1) conventional (splinted open …
Objectives
This study aimed to compare the accuracy of implant‐level conventional and digital impressions for atrophied maxillary ridges.
Materials and Methods
Twelve participants with atrophied edentulous maxillary ridges received six implants. Six months later and after soft tissue maturation around healing abutments, a control cast was constructed using the final passive restoration for each patient. Two types of implant‐level impression techniques were carried out for each patient: (1) conventional (splinted open‐tray) impression technique and (2) digital impression technique. For both techniques, scan bodies were labeled from the most distal implant on the left side (A, B, C, D, E, and F) and scanning was made. Accuracy of both techniques was measured using in vitro (two‐dimensional and three‐dimensional) and in vivo (clinical) methods. Two‐dimensional methods include measurement of the difference in linear distances AB, AC AD, AE, and AF. Geomagic software was used to assess the three‐dimensional deviation between the two impression techniques using the superimposition of standard tessellation language files. The incidence and percentage of nonpassive frameworks and framework misfits of final restorations for both types of impression techniques were assessed using the single screw test.
Results
For all distances, digital impressions recorded significantly higher deviation from control measurements than conventional impressions. The highest two‐dimensional linear deviation was noted for AF distance and the lowest difference was noted for AB distance. For all scan bodies, digital impressions recorded significantly higher three‐dimensional deviation than conventional impressions. The highest three‐dimensional deviation was noted with scan bodies C and D. Digital impressions recorded a significantly higher incidence of nonpassive frameworks and framework misfits than digital impressions.
Conclusion
Within the limitations of this study, it could be concluded that the conventional implant‐level impression technique showed greater in vitro and in vivo accuracy than the digital impression technique when used for full‐arch maxillary fixed restorations on inclined implants.
Wiley Online Library
以上显示的是最相近的搜索结果。 查看全部搜索结果