Augmentation techniques for rotator cuff repair

R Papalia, F Franceschi, B Zampogna… - British medical …, 2013 - academic.oup.com
British medical bulletin, 2013academic.oup.com
Introduction There is a high rate of recurrence of tear and failed healing after rotator cuff
repair. Several strategies have proposed to augment rotator cuff repairs to improve
postoperative outcome and shoulder performance. We systematically review the literature
on clinical outcome following rotator cuff augmentation. Sources of data We performed a
comprehensive search of Medline, CINAHL, Embase and the Cochrane Central Registry of
Controlled Trials, from inception of the database to 20 June 2012, using various …
Introduction
There is a high rate of recurrence of tear and failed healing after rotator cuff repair. Several strategies have proposed to augment rotator cuff repairs to improve postoperative outcome and shoulder performance. We systematically review the literature on clinical outcome following rotator cuff augmentation.
Sources of data
We performed a comprehensive search of Medline, CINAHL, Embase and the Cochrane Central Registry of Controlled Trials, from inception of the database to 20 June 2012, using various combinations of keywords. The reference lists of the previously selected articles were then examined by hand. Only studies focusing on clinical outcomes of human patients who had undergone augmented rotator cuff repair were selected. We then evaluated the methodological quality of each article using the Coleman methodology score (CMS), a 10 criteria scoring list assessing the methodological quality of the selected studies (CMS).
Areas of agreement
Thirty-two articles were included in the present review. Two were retrospective studies, and 30 were prospective. Biologic, synthetic and cellular devices were used in 24, 7 and 1 studies, respectively. The mean modified Coleman methodology score was 64.0.
Areas of controversy
Heterogeneity of the clinical outcome scores makes it difficult to compare different studies.
Growing points
None of the augmentation devices available is without problems, and each one presents intrinsic weaknesses. There is no dramatic increase in clinical and functional assessment after augmented procedures, especially if compared with control groups.
Research
More and better scientific evidence is necessary to use augmentation of rotator cuff repairs in routine clinical practice.
Oxford University Press
以上显示的是最相近的搜索结果。 查看全部搜索结果

Google学术搜索按钮

example.edu/paper.pdf
查找
获取 PDF 文件
引用
References