Control algorithms based on the active and non‐active currents for a UPQC without series transformers
IET Power Electronics, 2016•Wiley Online Library
This study presents control algorithms for a new unified power quality conditioner (UPQC)
without the series transformers that are frequently used to make the insertion of the series
converter of the UPQC between the power supply and the load. The behaviour of the
proposed UPQC is evaluated in presence of voltage imbalances, as well as under non‐
sinusoidal voltage‐and current conditions. The presented algorithms derive from the
concepts involving the active and non‐active currents, together with a phase‐locked‐loop …
without the series transformers that are frequently used to make the insertion of the series
converter of the UPQC between the power supply and the load. The behaviour of the
proposed UPQC is evaluated in presence of voltage imbalances, as well as under non‐
sinusoidal voltage‐and current conditions. The presented algorithms derive from the
concepts involving the active and non‐active currents, together with a phase‐locked‐loop …
This study presents control algorithms for a new unified power quality conditioner (UPQC) without the series transformers that are frequently used to make the insertion of the series converter of the UPQC between the power supply and the load. The behaviour of the proposed UPQC is evaluated in presence of voltage imbalances, as well as under non‐sinusoidal voltage‐and current conditions. The presented algorithms derive from the concepts involving the active and non‐active currents, together with a phase‐locked‐loop circuit. Based on these real‐time algorithms, and considering the proposed hardware topology, the UPQC is able to compensate the harmonic components of the voltages and currents, correct the power factor, and keep the load voltages regulated, all of this in a dynamic way, responding instantaneously to changes in the loads or in the electrical power system. The control algorithms were distributed in a two‐DSP digital control architecture, without any communication between them. Consequently, can be increased the sampling frequency of the acquired voltages and currents and improve the UPQC performance. Furthermore, some constraints of the proposed UPQC are evidenced, particularly when the main voltages are imbalanced. Simulation and experimental results are presented to verify the UPQC performance under transient and steady state conditions.
Wiley Online Library
以上显示的是最相近的搜索结果。 查看全部搜索结果