… : inter-laboratory evaluation of a simplified technique for isotope dilution mass spectrometry (IDMS). Part 1: Methodology for high accuracy analysis of trace metals

R Harte, G Newman, M Sargent - Accreditation and quality assurance, 2004 - Springer
standards for the isotope dilution analysis. The necessary spreadsheets were provided to aid
in the IDMS … required to produce the appropriate isotopic target blends. Two concentrations …

Characterisation of reference materials by isotope dilution mass spectrometry

J Vogl - Journal of Analytical Atomic Spectrometry, 2007 - pubs.rsc.org
… In general, it can be stated that IDMS is the most important … arrays for achieving higher
isotope ratio reproducibility, … following ISO and EURACHEM guidelines. Software packages for …

[引用][C] Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS)

M Sargent - 2002 - books.google.com
Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS)
Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS) …

[引用][C] Mike Sargent, Chris Harrington, Rita Harte (Eds): Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS)

J Vogl - Analytical and Bioanalytical Chemistry, 2003 - Springer
isotope-dilution mass spectrometry (IDMS) is regarded as one of the most powerful and most
accurate … The main reason for the success of IDMS is that it requires only isotope-ratio mea…

Development of a high ratio isotope dilution mass spectrometry calibration technique for chemical metrology

R Hearn, P Evans, M Sargent - … of Analytical Atomic Spectrometry, 2005 - pubs.rsc.org
… / 34 S of 14, achieving accuracy and uncertainty comparable with … blend isotope ratio within
this range is selected, guidance for … that the accuracy of this IDMS technique for high analyte …

Achieving traceable chemical measurements: inter-laboratory evaluation of a simplified technique for isotope dilution mass spectrometry. Part 2. Methodology for high …

M Sargent, G Newman, K Webb - Accreditation and quality assurance, 2004 - Springer
… The IDMS methodology described in this work incorporates a … difficulty of routinely achieving
high accuracy measurements. … extensive guidelines for achieving high accuracy in IDMS, …

Isotope-dilution ICP–MS for trace element determination and speciation: from a reference method to a routine method?

KG Heumann - Analytical and bioanalytical chemistry, 2004 - Springer
… inductively coupled plasma–isotope dilution mass spectrometry (ICP–IDMS) is suitable as
a … require mass-bias correction; this can be achieved by analyzing isotope standards under …

Isotope dilution mass spectrometry for absolute quantification in proteomics: concepts and strategies

J Villanueva, M Carrascal, J Abian - Journal of proteomics, 2014 - Elsevier
… these internal standards, especially in studies where a high number of … Isotope dilution
mass spectrometry (IDMS) is the optimum … To achieve this goal, both calibration standards and …

[PDF][PDF] Isotope Dilution Mass Spectrometry–A primary method of measurement and its role for RM certification

J Vogl, W Pritzkow - 2009 - Citeseer
… the application of isotope dilution mass spectrometry (IDMS) to … arrays for achieving higher
isotope ratio reproducibility … , however, the IDMS analysis does not fulfil the requirements of a …

An accurate and transferable protocol for reproducible quantification of organic pollutants in human serum using direct isotope dilution mass spectrometry

AJ Boggess, GMM Rahman, M Pamukcu, S Faber… - Analyst, 2014 - pubs.rsc.org
… -D-IDMS significantly improved quantitative accuracy and … certified standards traceable to
the National Institute of Standards … while simultaneously achieving accurate quantification to …