Initial experience with the use of an expandable titanium cage as a vertebral body replacement in patients with tumors of the spinal column: a report of 95 patients

A Viswanathan, MM Abd-El-Barr, E Doppenberg… - European Spine …, 2012 - Springer
A Viswanathan, MM Abd-El-Barr, E Doppenberg, D Suki, Z Gokaslan, E Mendel, G Rao
European Spine Journal, 2012Springer
Objective Vertebral body resection to treat spine tumors necessitates reconstruction to
maintain spinal stability. The durability of reconstruction may be a challenge in cancer
patients as treatment with chemotherapy and/or radiation coupled with poor nutritional status
may compromise bone quality. We present a series of patients who underwent implantation
of an expandable titanium cage (ETC) for reconstruction after vertebral body resection for
primary or metastatic spine tumors. We report the functional outcome, assess the durability …
Objective
Vertebral body resection to treat spine tumors necessitates reconstruction to maintain spinal stability. The durability of reconstruction may be a challenge in cancer patients as treatment with chemotherapy and/or radiation coupled with poor nutritional status may compromise bone quality. We present a series of patients who underwent implantation of an expandable titanium cage (ETC) for reconstruction after vertebral body resection for primary or metastatic spine tumors. We report the functional outcome, assess the durability of reconstruction, and describe complications associated with this procedure.
Methods
A retrospective review of patients undergoing placement of ETC after vertebrectomy for spinal tumor at our institution was performed.
Results
From September 2001 to August 2006, 95 patients underwent implantation of an ETC for reconstruction of the anterior spinal column following vertebrectomy for tumor (75 one-level, 19 two-level, 1 three-level). All patients underwent spinal stabilization as well. The median survival after surgery was 13.7 months; 23 patients had primary spinal tumors and 72 had metastatic tumors. Numerical pain scores were significantly improved postoperatively indicating a palliative benefit. No new neurological deficits were noted postoperatively, except when intentional neurological sacrifice was performed for oncologic reasons. Median height correction of 14% (range 0–118%) and median improvement in sagittal alignment of 6° (range 0–28°) were demonstrated on immediate postoperative imaging. Three patients experienced hardware related complications, one of which had posterior migration of the ETC. On postoperative imaging, 12 patients demonstrated subsidence of greater than 1 mm, but none required operative revision.
Conclusion
Use of an ETC for spinal reconstruction in patients with spinal tumors is safe, decreases pain associated with pathologic fracture, protects neurologic function, and is durable. We found a very low incidence of cage-related construct failures and no significant problems with subsidence.
Springer
以上显示的是最相近的搜索结果。 查看全部搜索结果