Inter-and intraradiologist variability in the BI-RADS assessment and breast density categories for screening mammograms

A Redondo, M Comas, F Macia, F Ferrer… - The British journal of …, 2012 - academic.oup.com
A Redondo, M Comas, F Macia, F Ferrer, C Murta-Nascimento, MT Maristany, E Molins…
The British journal of radiology, 2012academic.oup.com
Objective The aim of this study was to evaluate reader variability in screening mammograms
according to the American College of Radiology Breast Imaging Reporting and Data System
(BI-RADS) assessment and breast density categories. Methods A stratified random sample
of 100 mammograms was selected from a population-based breast cancer screening
programme in Barcelona, Spain: 13 histopathologically confirmed breast cancers and 51
with true-negative and 36 with false-positive results. 21 expert radiologists from radiological …
Objective
The aim of this study was to evaluate reader variability in screening mammograms according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) assessment and breast density categories.
Methods
A stratified random sample of 100 mammograms was selected from a population-based breast cancer screening programme in Barcelona, Spain: 13 histopathologically confirmed breast cancers and 51 with true-negative and 36 with false-positive results. 21 expert radiologists from radiological units of breast cancer screening programmes in Catalonia, Spain, reviewed the mammography images twice within a 6-month interval. The readers described each mammography using BI-RADS assessment and breast density categories. Inter- and intraradiologist agreement was assessed using percentage of concordance and the kappa (κ) statistic.
Results
Fair interobserver agreement was observed for the BI-RADS assessment [κ=0.37, 95% confidence interval (CI) 0.36–0.38]. When the categories were collapsed in terms of whether additional evaluation was required (Categories III, 0, IV, V) or not (I and II), moderate agreement was found (κ=0.53, 95% CI 0.52–0.54). Intra-observer agreement for BI-RADS assessment was moderate using all categories (κ=0.53, 95% CI 0.50–0.55) and substantial on recall (κ=0.66, 95% CI 0.63–0.70). Regarding breast density, inter- and intraradiologist agreement was substantial (κ=0.73, 95% CI 0.72–0.74 and κ=0.69, 95% CI 0.68–0.70, respectively).
Conclusion
We observed a substantial intra-observer agreement in the BI-RADS assessment but only moderate interobserver agreement. Both inter- and intra-observer agreement in mammographic interpretation of breast density was substantial.
Advances in knowledge
Educational efforts should be made to decrease radiologists' variability in BI-RADS assessment interpretation in population-based breast screening programmes.
Oxford University Press
以上显示的是最相近的搜索结果。 查看全部搜索结果