[HTML][HTML] Measurement and analysis of movement of BPM vacuum chamber for HLS

C Yong, SUN Bao-Gen, HE Duo-Hui… - Chinese …, 2008 - zgwlc.xml-journal.net
C Yong, SUN Bao-Gen, HE Duo-Hui, LI Jian-Wei, LI Chuan, X Ke, W Ji-Gang, LU Ping
Chinese Physics C, 2008zgwlc.xml-journal.net
The beam horizontal orbit at Hefei Light Source (HLS) was drifting all along while the
storage ring was operating. To study this phenomenon, the displacement and the
temperature variation of the BPM chamber were measured. By analyzing the measurement
results, the main reason that explained the drifting phenomenon was found. The vacuum
chamber following the dipole magnets was heated by the synchrotron light, which caused
the increasing of the chamber surface temperature. The variation of the chamber …
Abstract
The beam horizontal orbit at Hefei Light Source (HLS) was drifting all along while the storage ring was operating. To study this phenomenon, the displacement and the temperature variation of the BPM chamber were measured. By analyzing the measurement results, the main reason that explained the drifting phenomenon was found. The vacuum chamber following the dipole magnets was heated by the synchrotron light, which caused the increasing of the chamber surface temperature. The variation of the chamber temperature was
zgwlc.xml-journal.net