过去一年中添加的文章,按日期排序
Experience with patient-specific quality assurance of dosimetrist-led online adaptive prostate SBRT
JF Calvo-Ortega, C Laosa-Bello… - Journal of Medical …, 2024 - Elsevier
4 天前 - … planning treatment plans with the Eclipse system, … used Monte Carlo software to
investigate the accuracy of M3D in the verification of our online adaptive prostate SBRT plans, …
investigate the accuracy of M3D in the verification of our online adaptive prostate SBRT plans, …
[PDF][PDF] Deep-Learning for Rapid Estimation of the Out-of-Field Dose in External Beam Photon Radiation Therapy− A Proof of Concept
C Alapetite, V Grégoire, E Deutsch, I Diallo, C Robert - scholar.archive.org
19 天前 - … in research, including Monte Carlo simulations and analytical … Treatment planning
systems are used in clinical routine to … For the validation, we chose to select 2 devices: a …
systems are used in clinical routine to … For the validation, we chose to select 2 devices: a …
Therapeutic Helium Beam Biophysical Characterization: In-and Out-of-Field Microdosimetry and Rbe
37 天前 - … By comparing experimental data with TOPAS Monte Carlo … for the clinical treatment
planning system (TPS) [10] [12]. … validation and should be addressed to improve treatment …
planning system (TPS) [10] [12]. … validation and should be addressed to improve treatment …
Evolution of dose distribution for a 125I eye plaque using MCNPX and Plaque Simulator software
H Poorbaygi, E Sardari, SMR Aghamiri… - Precision Radiation …, 2024 - Wiley Online Library
48 天前 - … 125I seeds to treat ocular melanoma using Monte Carlo N-… Results: In the validation,
the maximum relative difference … software for clinical treatment planning of complex, Monte …
the maximum relative difference … software for clinical treatment planning of complex, Monte …
From radiobiology to radiotherapy: dose homogeneity in cells after alpha irradiation in measurements and Monte Carlo simulations
M Filipek, B Pszczółkowska-Kępa, B Kociński… - Polish Journal of …, 2024 - sciendo.com
65 天前 - … in Matter) is a software package used for studying in the … our studies dose distribution
should be verified based on … in 3D radiotherapy planning is gamma 3%/3mm. Distributions …
should be verified based on … in 3D radiotherapy planning is gamma 3%/3mm. Distributions …
Practical experience with initial quality assurance of a high dose rate brachytherapy grid‐based Boltzmann solver algorithm
JM Fagerstrom - Journal of Applied Clinical Medical Physics, 2024 - Wiley Online Library
81 天前 - … BV, for high dose rate brachytherapy treatment planning for a … dose check software
was used to evaluate dose … between Monte Carlo and Acuros BV dose distributions were …
was used to evaluate dose … between Monte Carlo and Acuros BV dose distributions were …
Monte Carlo for Preclinical Radiotherapy
R Tummala - 2024 - knowledge.uchicago.edu
87 天前 - … validation tool for faster dose calculation algorithms, especially in higher order
treatment planning and inverse planning… be an important tool for treatment planning software and …
treatment planning and inverse planning… be an important tool for treatment planning software and …
Deep learning based linear energy transfer calculation for proton therapy
X Tang, HWC Tseung, D Moseley… - Physics in Medicine …, 2024 - iopscience.iop.org
88 天前 - … within proton treatment planning systems. Approach. 275 4… MC commissioning and
clinical plan verification, we opt for … to Dr Pepin for his help with the Monte Carlo simulations. …
clinical plan verification, we opt for … to Dr Pepin for his help with the Monte Carlo simulations. …
[HTML][HTML] Alanine dosimeters for LET measurement in proton radiotherapy
B Michalec, L Stolarczyk, N Bassler, M Rydygier… - Radiation …, 2024 - Elsevier
90 天前 - … treatment planning systems in the clinic needs to be preceded by commissioning
and comprehensive end-to-end testing, which requires specific tools to verify … on Monte Carlo …
and comprehensive end-to-end testing, which requires specific tools to verify … on Monte Carlo …
The potential of mixed carbon-helium beams for online treatment verification: a simulation and treatment planning study
JJ Hardt, AA Pryanichnikov, N Homolka… - Physics in Medicine …, 2024 - iopscience.iop.org
93 天前 - … to develop a software framework for treatment planning and motion verification in
range-… were simulated using the open-source Monte Carlo package TOPAS. Beam delivery …