Patient‐adaptive magnetic resonance oximetry: Comparison with invasive catheter measurement of blood oxygen saturation in patients with cardiovascular disease

J Varghese, M Smyke, Y Pan, S Rajpal… - Journal of Magnetic …, 2020 - Wiley Online Library
J Varghese, M Smyke, Y Pan, S Rajpal, J Craft, LC Potter, SV Raman, R Ahmad
Journal of Magnetic Resonance Imaging, 2020Wiley Online Library
Background The current standard method to measure intracardiac oxygen (O2) saturation is
by invasive catheterization. Accurate noninvasive blood O2 saturation by MRI could
potentially reduce the duration and risk of invasive diagnostic procedures. Purpose To
noninvasively determine blood oxygen saturation in the heart with MRI and compare the
accuracy with catheter measurements. Study Type Prospective. Subjects Thirty‐two patients
referred for right heart catheterization (RHC) and five healthy subjects. Field …
Background
The current standard method to measure intracardiac oxygen (O2) saturation is by invasive catheterization. Accurate noninvasive blood O2 saturation by MRI could potentially reduce the duration and risk of invasive diagnostic procedures.
Purpose
To noninvasively determine blood oxygen saturation in the heart with MRI and compare the accuracy with catheter measurements.
Study Type
Prospective.
Subjects
Thirty‐two patients referred for right heart catheterization (RHC) and five healthy subjects.
Field Strength/Sequence
T2‐prepared single‐shot balanced steady‐state free‐precession at 1.5T.
Assessment
MR signals in venous and arterial blood, hematocrit, and arterial O2 saturation from a pulse oximeter were jointly processed to fit the Luz–Meiboom model and estimate blood O2 saturation in the right heart. Interstudy reproducibility was evaluated in volunteers and patients. Interobserver reproducibility among three readers was assessed using data from volunteers and 10 patients. Accuracy of MR oximetry was compared to RHC in all patients.
Statistical Tests
Coefficient of variation, intraclass correlation coefficient, Bland–Altman analysis, Pearson's correlation.
Results
The coefficient of variation for interstudy reproducibility of O2 saturation was 2.6% on average in volunteers and 3.2% in patients. Interobserver reproducibility among three observers yielded intraclass correlation coefficients of 0.81 and 0.87 respectively for RV and MPA O2 saturation. O2 saturation (y = 0.85x + 0.13, R = 0.78) and (a‐v)O2 difference (y = 0.71x + 0.90, R = 0.69) by MR and RHC were significantly correlated (N = 32, P < 0.05 in both cases) in patients. MR slightly overestimated O2 saturation compared to RHC with 2% ± 5% bias and limits of agreement between −7% and 12%.
Data Conclusion
MR oximetry is repeatable and reproducible. Good agreement was shown between MR and catheter venous O2 saturation and (a‐v)O2 difference in a cohort whose venous O2 ranged from abnormally low to high levels, with most values in the normal physiological range.
Level of Evidence
2.
Technical Efficacy Stage
2.