[PDF][PDF] Technical design report for the PANDA forward spectrometer calorimeter
Panda Collaboration - arXiv preprint arXiv:1704.02713, 2017 - arxiv.org
… This document is devoted to the electromagnetic calorimeter of the Forward Spectrometer
and describes the design considerations, the technical layout, the expected performance, and …
and describes the design considerations, the technical layout, the expected performance, and …
[PDF][PDF] PANDA forward spectrometer calorimeter
PA Semenov, SI Bukreeva… - Proceedings of …, 2016 - researchgate.net
… -type sampling calorimeter. The design of the PANDA Forward Spectrometer Calorimeter
(… FSC Technical Design Report recently was approved by FAIR experts committee and …
(… FSC Technical Design Report recently was approved by FAIR experts committee and …
The electromagnetic calorimeter for the PANDA target spectrometer
…, HG Zaunick, PANDA collaboration - Journal of Physics …, 2019 - iopscience.iop.org
… into a target spectrometer and a forward spectrometer. Both parts … calorimeters within
strong magnetic fields. A detailed schematic can be found in the Fig. 1. The PANDA calorimeters …
strong magnetic fields. A detailed schematic can be found in the Fig. 1. The PANDA calorimeters …
Construction of the Forward Endcap Calorimeter of the PANDA Experiment at FAIR
T Held, PANDA Collaboration - Journal of Physics: Conference …, 2019 - iopscience.iop.org
… spectrometer part is built as a homogeneous calorimeter in … forward spectrometer a Shashlyk
type sampling calorimeter … The crystal material for the target calorimeters is an improved …
type sampling calorimeter … The crystal material for the target calorimeters is an improved …
The forward endcap of the electromagnetic calorimeter for the PANDA detector at FAIR
…, forthe PANDA collaboration - Journal of Physics …, 2015 - iopscience.iop.org
… Therefore the PANDA spectrometer is split into a target spectrometer based on a 2 T … and
a forward 16th International Conference on Calorimetry in High Energy Physics (CALOR 2014) …
a forward 16th International Conference on Calorimetry in High Energy Physics (CALOR 2014) …
PANDA electromagnetic calorimeters
…, OP Yushchenko, Panda Collaboration - … , Spectrometers …, 2009 - Elsevier
… All collected light from a calorimeter cell goes through … PANDA case, since forward
spectrometer EMC is proposed to be situated outside of the magnetic field. This type of the …
spectrometer EMC is proposed to be situated outside of the magnetic field. This type of the …
Performance of the prototype of the electromagnetic calorimeter for PANDA
…, G Tambave, A Wilms, Panda Collaboration - … , Spectrometers …, 2011 - Elsevier
… , the detector is split into a target spectrometer, located inside a 2 T superconducting …
forward spectrometer based on a 2 Tm dipole magnet for small-angle tracks. In both spectrometer …
forward spectrometer based on a 2 Tm dipole magnet for small-angle tracks. In both spectrometer …
Design studies of the PWO Forward End-cap calorimeter for PANDA
P̄ANDA Collaboration http://www-panda. gsi … - The European Physical …, 2013 - Springer
… design of the Forward End-cap calorimeter and analyzes the response of the Forward End-cap
calorimeter in … Schematic view of the PANDA detector consisting of Target Spectrometer (…
calorimeter in … Schematic view of the PANDA detector consisting of Target Spectrometer (…
The electromagnetic calorimetry of the PANDA detector at FAIR
RW Novotny, PANDA collaboration - Journal of Physics …, 2012 - iopscience.iop.org
… The electromagnetic calorimeters are composed of a target spectrometer (… forward end
cap as major components of the electromagnetic calorimeter of the PANDA target spectrometer (…
cap as major components of the electromagnetic calorimeter of the PANDA target spectrometer (…
[PDF][PDF] Technical Design Report for: PANDA Forward Time of Flight detector (FToF wall)
P Collaboration - 2018 - panda.gsi.de
… Forward Spectrometer of the PANDA experiment. This document describes in details the
design … eg, with FRICH or Forward (Shashlyk) Calorimeter, or Forward Muon range system, and …
design … eg, with FRICH or Forward (Shashlyk) Calorimeter, or Forward Muon range system, and …