Real-time checking of electronic anesthesia records for documentation errors and automatically text messaging clinicians improves quality of documentation

WS Sandberg, EH Sandberg, AR Seim… - Anesthesia & …, 2008 - journals.lww.com
Anesthesia information management systems (AIMS) record data into a database during
anesthesia… synchronously with the creation of the anesthesia record for “errors” that are defined …

Influencing anesthesia provider behavior using anesthesia information management system data for near real-time alerts and post hoc reports

RH Epstein, F Dexter, N Patel - Anesthesia & Analgesia, 2015 - journals.lww.com
… near real-time feedback to providers reduces the occurrence of such gaps in the electronic
anesthesia record, … For example, in our process that checks to see whether documentation of …

[HTML][HTML] A systematic review of near real-time and point-of-care clinical decision support in anesthesia information management systems

AF Simpao, JM Tan, AM Lingappan, JA Gálvez… - Journal of clinical …, 2017 - Springer
… Virtually all present-day AIMS have the core functionality of anesthetic record keeping
combined with the ability to implement basic CDS. Real-time and near real-time CDS can be …

An observational study of the accuracy and completeness of an anesthesia information management system: recommendations for documentation system changes

BA Wilbanks, JA Moss, ES Berner - CIN: Computers, Informatics …, 2013 - journals.lww.com
anesthetic record can self-audit in real time to ensure that all required data fields are
present and can also perform an error check prior to finalizing the electronic healthcare record; …

Improving documentation of a beta-blocker quality measure through an anesthesia information management system and real-time notification of documentation errors

BG Nair, GN Peterson, SF Newman, WY Wu… - The Joint Commission …, 2012 - Elsevier
anesthesia record, allows the anesthesia provider to easily document his or her care by having
automated interfaces to the patient monitor, the anesthesia … , we plan to check the validity …

A randomized trial of automated electronic alerts demonstrating improved reimbursable anesthesia time documentation

RE Freundlich, CS Barnet, MR Mathis… - … of clinical anesthesia, 2013 - Elsevier
… t-test compliance comparisons reported a P-value > 0.05 for the Levene's test for equality of
… to decrease the number of unbillable anesthesia records, resulting in an estimated increase …

Automatic notifications mediated by anesthesia information management systems reduce the frequency of prolonged gaps in blood pressure documentation

JM Ehrenfeld, RH Epstein, S Bader… - Anesthesia & …, 2011 - journals.lww.com
… We evaluated 212,706 electronic anesthesia records from 3 large academic centers. We …
Again, we applied the Student t test to the transformed percentages to determine statistical …

Detection of intraoperative incidents by electronic scanning of computerized anesthesia records: comparison with voluntary reporting

KV Sanborn, J Castro, M Kuroda… - … of Anesthesiologists, 1996 - pubs.asahq.org
… was checked for voluntary reporting. … anesthesia records was compared with our institution's
"in-hospital mortality" database. The hospital's mortality database was consulted for a time

Automated correction of room location errors in anesthesia information management systems

RH Epstein, F Dexter, E Piotrowski - Anesthesia & Analgesia, 2008 - journals.lww.com
… of the patient are also supposed to check the cases they have open in their … actual locations
from the workstations where defined events were entered, because the anesthetic record

Anesthesia information management system-based near real-time decision support to manage intraoperative hypotension and hypertension

BG Nair, M Horibe, SF Newman, WY Wu… - Anesthesia & …, 2014 - journals.lww.com
real-time arterial blood pressure data automatically and at a higher frequency when compared
with paper anesthesia records… notifications were instituted (Mann Whitney rank sum test, P …