Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome.
JC Meurice, I Marc, F Sériès - … journal of respiratory and critical care …, 1996 - atsjournals.org
… We conclude that (1) the amount of use during CPAP treatment is higher with autoCPAPthan
with constant-CPAP, and (2) Morphee + auto-CPAP is as efficient as conventional CPAP in …
with constant-CPAP, and (2) Morphee + auto-CPAP is as efficient as conventional CPAP in …
Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome.
P Lloberes, E Ballester, JM Montserrat… - American journal of …, 1996 - atsjournals.org
… tained with PSGwith that obtained with auto-CPAP. There were no significant differences …
auto-CPAP. Asa secondary analysis, we analyzed auto-CPAP performance with regard to sleep…
auto-CPAP. Asa secondary analysis, we analyzed auto-CPAP performance with regard to sleep…
Evaluation of the apnea-hypopnea index determined by the S8 auto-CPAP, a continuous positive airway pressure device, in patients with obstructive sleep apnea …
K Ueno, T Kasai, G Brewer, H Takaya… - … of Clinical Sleep …, 2010 - jcsm.aasm.org
… while patients are on CPAP have come into clinical use. The purpose of this study was to
compare the apnea-hypopnea index (AHI) determined by the S8 auto-CPAP device with the …
compare the apnea-hypopnea index (AHI) determined by the S8 auto-CPAP device with the …
Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea
CA Nigro, S González, A Arce, MR Aragone… - Sleep and Breathing, 2015 - Springer
… auto-CPAP device for the diagnosis of residual sleep apnea … of residual sleep apnea in
patients treated with CPAP. On the … to define residual sleep apnea by the auto-CPAP devices. …
patients treated with CPAP. On the … to define residual sleep apnea by the auto-CPAP devices. …
The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea
RB Berry, JM Parish, KM Hartse - Sleep, 2002 - academic.oup.com
… the potential problems with automated CPAP titration. Most of … on auto-CPAP behaviour
during sleep in sleep apnea/… manual and automatic cpap titration in patients with sleep apnea/…
during sleep in sleep apnea/… manual and automatic cpap titration in patients with sleep apnea/…
Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome
JC Meurice, A Cornette, F Philip-Joet, JL Pepin… - Sleep medicine, 2007 - Elsevier
… We compared the clinical effectiveness of fixed pressure CPAP and four different autoCPAP
… constant CPAP group and evaluate residual apnea/hypopnea index (AHI) under autoCPAP. …
… constant CPAP group and evaluate residual apnea/hypopnea index (AHI) under autoCPAP. …
Effective comparison of two auto-CPAP devices for treatment of obstructive sleep apnea based on polysomnographic evaluation
HB Shi, L Cheng, M Nakayama, Y Kakazu, M Yin… - Auris Nasus …, 2005 - Elsevier
… Automatic continuous positive airway pressure (auto-CPAP) machines have increased in …
sleep apnea syndrome (OSAS) during the last decade. Ideally, these devices can automatically …
sleep apnea syndrome (OSAS) during the last decade. Ideally, these devices can automatically …
Accuracy of autotitrating CPAP to estimate the residual apnea–hypopnea index in patients with obstructive sleep apnea on treatment with autotitrating CPAP
… to determine the accuracy of auto-CPAP in estimating the residual AHI in patients with
obstructive sleep apnea (OSA) who were treated with auto-CPAP without a CPAP titration study. …
obstructive sleep apnea (OSA) who were treated with auto-CPAP without a CPAP titration study. …
Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea
JH Ficker, GH Wiest, G Lehnert, B Wiest, EG Hahn - Thorax, 1998 - thorax.bmj.com
… effectiveness of the auto-CPAP machine investigated. … the auto-CPAP device and the
conventional CPAP machine in terms of the number of residual apnoeas and hypopnoeas, sleep …
conventional CPAP machine in terms of the number of residual apnoeas and hypopnoeas, sleep …
Effects of fixed compared to automatic CPAP on sleep in obstructive sleep apnoea syndrome
O Resta, P Carratù, A Depalo… - Monaldi archives for …, 2004 - monaldi-archives.org
… that CPAP administered by a fixed CPAP machine and by the Autoset T autoCPAP device
… variations during application of an autotitration CPAP machine in obstructive sleep apnea …
… variations during application of an autotitration CPAP machine in obstructive sleep apnea …
相关搜索
- auto cpap sleep apnea hypopnea
- fixed cpap sleep apnea
- autotitrating cpap sleep apnea
- airway pressure sleep apnea
- patients with obstructive sleep apnea syndrome
- auto cpap sleep apnoea
- auto cpap residual apnea hypopnea index
- residual sleep apnea cpap therapy
- practice parameters obstructive sleep apnea syndrome
- sleep apnea syndrome cpap treatment
- automatic cpap titration obstructive sleep apnoea
- meta analysis sleep apnea
- randomized controlled trial sleep apnea
- auto cpap therapy sleep stage
- auto cpap device obstructive sleep apnoea
- auto cpap treatment obstructive sleep apnoea