A durable porcine pericardial surgical bioprosthetic heart valve: a proof of concept
… of surgical and transcatheter cardiac valve replacements. This study develops a new surgical
bioprosthesis, using porcine pericardial leaflets. Porcine pericardium was obtained from …
bioprosthesis, using porcine pericardial leaflets. Porcine pericardium was obtained from …
Bovine pericardium versus porcine aortic valve: comparison of tissue biological properties as prosthetic valves
K Liao, E Seifter, D Hoffman, EL Yellin… - Artificial …, 1992 - Wiley Online Library
… that bovine pericardium has superior intrinsic biological properties for prosthetic valve
manufacture… it will in some applications be superior to the porcine aortic valve. Key Words: Bovine …
manufacture… it will in some applications be superior to the porcine aortic valve. Key Words: Bovine …
Evaluation of transcatheter heart valve biomaterials: Biomechanical characterization of bovine and porcine pericardium
… Bovine pericardium (BP) has been identified as a choice biomaterial for the development
of surgical bioprosthetic heart valves (BHV) and transcatheter aortic valves (TAV). …
of surgical bioprosthetic heart valves (BHV) and transcatheter aortic valves (TAV). …
Durability of pericardial versus porcine aortic valves
G Gao, YX Wu, GL Grunkemeier, AP Furnary… - Journal of the American …, 2004 - jacc.org
… The primary outcome of interest in this analysis was bioprosthetic valve dysfunction. This
was defined as any clinically relevant valvular stenosis or insufficiency documented by …
was defined as any clinically relevant valvular stenosis or insufficiency documented by …
Porcine versus pericardial bioprostheses: a comparison of late results in 1,593 patients
LC Pelletier, M Carrier, Y Leclerc, G Lepage… - The Annals of thoracic …, 1989 - Elsevier
… pericardial and porcine bioprostheses in terms of patient survival, valve survival, and valve-…
Thus, in the aortic position, pericardial valves compare with porcine valves up to 6 years, …
Thus, in the aortic position, pericardial valves compare with porcine valves up to 6 years, …
[HTML][HTML] Durability of pericardial versus porcine bioprosthetic heart valves
GL Grunkemeier, AP Furnary, YX Wu, L Wang… - The Journal of thoracic …, 2012 - Elsevier
… Through the end of 2010, we had implanted 506 porcine and 2449 pericardial aortic valves
and 181 porcine and 163 pericardial mitral valves. The corresponding total and maximum …
and 181 porcine and 163 pericardial mitral valves. The corresponding total and maximum …
A biomechanical and microstructural analysis of bovine and porcine pericardium for use in bioprosthetic heart valves
G Campion, K Hershberger, A Whelan, J Conroy… - Structural …, 2021 - Taylor & Francis
… valve leaflet pericardial … porcine pericardial tissue would produce more consistent mechanical
properties, as areas with aligned collagen fibers are not consistently present in porcine …
properties, as areas with aligned collagen fibers are not consistently present in porcine …
Biomaterial characterization of off‐the‐shelf decellularized porcine pericardial tissue for use in prosthetic valvular applications
… In the current study, the impact of various treatment conditions on uniaxial loading was
assessed in porcine pericardium and was contrasted to both native pericardium and native …
assessed in porcine pericardium and was contrasted to both native pericardium and native …
Evaluation of transcatheter heart valve biomaterials: computational modeling using bovine and porcine pericardium
F Sulejmani, A Caballero, C Martin, T Pham… - Journal of the mechanical …, 2019 - Elsevier
… The durability of bioprosthetic heart valve (BHV) devices, commonly made of bovine (BP)
and porcine (PP) pericardium tissue, is partly limited by device calcification and tissue …
and porcine (PP) pericardium tissue, is partly limited by device calcification and tissue …
Bioengineered percutaneous heart valves for transcatheter aortic valve replacement: a comparative evaluation of decellularised bovine and porcine pericardia
SR Tuladhar, S Mulderrig, M Della Barbera… - Materials Science and …, 2021 - Elsevier
… Surgical bioprosthetic heart valves (… pericardial tissue can be effectively used to manufacture
functional replacements and clearly provide the novel indication that porcine pericardium …
functional replacements and clearly provide the novel indication that porcine pericardium …
相关搜索
- bovine and porcine pericardium
- porcine pericardial tissue
- decellularized porcine pericardium
- carpentier edwards pericardial bioprosthesis valve replacement
- twelve years porcine bioprosthetic valve
- patient survival porcine bioprosthetic valve
- bioprosthetic heart valves
- porcine aortic valves
- bioprosthetic valve failure
- porcine bioprosthetic cardiac valves
- alternative bioprosthetic heart valve material
- evolving geometry bioprosthetic heart valve leaflets
- pericardial valves 12 year clinical experience
- porcine valves 15 year outcome
- prosthetic valves bovine pericardium
- porcine aortic bovine pericardial valves