The future of bedside monitoring

R Kohli-Seth, JM Oropello - Critical care clinics, 2000 - Elsevier
monitor blood flow in the brain and skin grafts, or by intestinal tubes (eg, nasogastric) to monitor
changes in regional and mucosal blood flow… rather than quantitative (flow) assessment of …

Bedside monitoring of cerebral blood flow in patients with acute hemispheric stroke

E Keller, G Wietasch, P Ringleb, M Scholz… - Critical care …, 2000 - journals.lww.com
bedside serial CBF measurements that are easy to perform, with results available within 5
mins at the bedside, … Our first data indicate that bedside monitoring of CBF could be of clinical …

Functional hemodynamic monitoring: applied physiology at the bedside

MR Pinsky - Intensive Care Medicine: Annual Update 2002, 2002 - Springer
… a physiological condition wherein blood flow and oxygen … -based questions: 15 Will blood
flow to the body increase (or … of vascular tone or merely due to inadequate blood flow? …

Monitoring patients with continuous-flow ventricular assist devices outside of the intensive care unit: novel challenges to bedside nursing

G O'Shea, JJ Teuteberg… - Progress in …, 2013 - journals.sagepub.com
… Many monitoring machines derive results that are based on the principle that arterial blood
flow is pulsatile and that there is a certain variation in flow between the systolic and diastolic …

[HTML][HTML] Validation of frontal near-infrared spectroscopy as noninvasive bedside monitoring for regional cerebral blood flow in brain-injured patients

P Taussky, B O'Neal, WP Daugherty, S Luke… - Neurosurgical …, 2012 - thejns.org
… Current methods used to monitor cerebral hemodynamics have … Other bedside methods such
as jugular bulb oximetry … , real-time, bedside monitoring tool of cerebral oximetry in critically …

Optical bedside monitoring of cerebral blood flow in acute ischemic stroke patients during head-of-bed manipulation

CG Favilla, RC Mesquita, M Mullen, T Durduran, X Lu… - Stroke, 2014 - Am Heart Assoc
Bedside monitoring of cerebral blood flow (CBF) allows the effects of interventions such
as flat HOB to be monitored and may ultimately be used to guide clinical management. …

[HTML][HTML] Bench-to-bedside review: an approach to hemodynamic monitoring-Guyton at the bedside

S Magder - Critical care, 2012 - Springer
… by any monitoring device. When there is blood flow in the circulation, blood volume … of
the system for flow, the primary determinant of venous return under flow conditions is the …

[图书][B] Bedside monitoring of cerebral blood flow in patients with subarachnoid hemorrhage

T Hegner, N Krayenbühl, M Hefti, Y Yonekawa, E Keller - 2001 - Springer
… According to our standardized treatment regimen triple-H therapy was induced if TCD blood
flow velocities increased (middle cerebral artery mean blood flow velocities> 120 em/sec or …

New approaches to bedside monitoring in stroke

A Cyrous, B O'Neal, WD Freeman - Expert review of …, 2012 - Taylor & Francis
… Pressure autoregulation assumes cerebral blood flow = cerebral perfusion pressure/…
linear correlation between cerebral blood flow and cerebral perfusion pressure parameters. …

Computer supported multimodal bed-side monitoring for neuro intensive care

M Czosnyka, H Whitehouse, P Smielewski… - … of clinical monitoring …, 1994 - Springer
… The latest trends in neuro-intensive care include the continuous monitoring of transcranial
Doppler (TCD) blood flow velocity (FV) in basal cerebral arteries [1, 31, cortical red cell flux …