Potentialities of electrochemical detection in conjunction with non-aqueous capillary electrophoresis

FM Matysik - Electrochimica acta, 1998 - Elsevier
… The working electrode used in this study was a platinum microdisc electrode (disc diameter
25 … Fused silica capillaries with comparable outer diameters can easily be aligned above the …

Capillary electrophoresis coupled with electrochemiluminescence detection using porous etched joint

XB Yin, H Qiu, X Sun, J Yan, J Liu, E Wang - Analytical chemistry, 2004 - ACS Publications
working electrode accomplish alignment between the working electrode and the end of the
capillary. … between the end of the capillary and the working electrode can be about 100 μm in …

Portable capillary-based (non-chip) capillary electrophoresis

M Ryvolová, M Macka, J Preisler - TrAC Trends in Analytical Chemistry, 2010 - Elsevier
Capillary electrophoresis (CE), due to its main strengths of high separation efficiency, …
easy alignment of the capillary end and the detection electrode was achieved using an end-…

Determination of sulpiride by capillary electrophoresis with end-column electrogenerated chemiluminescence detection

J Liu, W Cao, H Qiu, X Sun, X Yang, E Wang - Clinical chemistry, 2002 - academic.oup.com
… end of the capillary by use of a separate working electrode (13) or was added in a small
reservoir at the interface between the separation capillary and the working electrode, which was …

[图书][B] Capillary electrophoresis: theory and practice

P Camilleri - 1997 - books.google.com
… Camilleri joined Shell Research, working on the physicochemical characterization of a
range of … to two platinum electrodes extending into buffer solution. The ends of the fused-silica …

A simple and low‐cost electrochemiluminescence detector for capillary electrophoresis

MT Chiang, MC Lu, CW Whang - Electrophoresis, 2003 - Wiley Online Library
working electrode either precisely aligned with the capillary tip [17–20] or directly inserted
into the capillary … ], or continuously delivered to the capillary end using a syringe pump and a …

Recent developments in electrochemical flow detections—a review: part I. Flow analysis and capillary electrophoresis

M Trojanowicz - Analytica chimica acta, 2009 - Elsevier
… of the surface of the indicator or working electrodes, reduction of response time and, in …
various techniques of capillary electrophoresis. Obviously, capillary electrophoresis (as well …

End-column electrochemical detection for inorganic and organic species in high-voltage capillary electrophoresis

W Lu, RM Cassidy, AS Baranski - Journal of Chromatography A, 1993 - Elsevier
… For more routine operation the capillary and the ultramicro working electrode were placed
on a glass plate; the desired position between the capillary and the electrode was adjusted …

Potentiometric detection in capillary electrophoresis with a metallic copper electrode

T Kappes, PC Hauser - Analytica chimica acta, 1997 - Elsevier
… The application of these electrodes as detectors in capillary electrophoresis has been reported
… The working electrode could be manoeuvred in front of the capillary end by means of a …

Amperometric detection of cytochrome c by capillary electrophoresis at a sol–gel carbon composite electrode

SN Tan, L Hua - Analytica chimica acta, 2001 - Elsevier
… A conventional three-electrode system was used with the Cu 2 O-… working electrode at the
end of the separation capillary. The reference electrode was a saturated calomel electrode (…