[HTML][HTML] Antitachycardia pacing programming in implantable cardioverter defibrillator: a systematic review

E De Maria, D Giacopelli, A Borghi… - World journal of …, 2017 - ncbi.nlm.nih.gov
… Implantable cardioverter defibrillator (ICD) programming involves several parameters. In
recent years antitachycardia pacing (ATP) has gained an increasing importance in the …

Empirical versus tested antitachycardia pacing in implantable cardioverter defibrillators: a prospective study including 200 patients

A Schaumann, F Mühlen, B Herse, BD Gonska… - Circulation, 1998 - Am Heart Assoc
… Background—Implantable cardioverter-defibrillators (ICDs) reduce the risk of sudden cardiac
death. The objective of this study was to evaluate whether testing of antitachycardia pacing

Implantable cardioverter defibrillator shock reduction using new antitachycardia pacing therapies

M Wathen - American heart journal, 2007 - Elsevier
The main purpose of ICDs is to abort sudden death by delivering therapy at the moment of
tachycardia. Shocks accomplish this goal but are painful. Alternatively antitachycardia pacing

Clinical predictors and efficacy of antitachycardia pacing in patients with implantable cardioverter defibrillators: the importance of the patient's sex

RW Peters, X Zhang, MR Gold - Pacing and Clinical …, 2001 - Wiley Online Library
… termination of pacing and to identify ineffective pacing strategies… in the 162 who received
antitachycardia pacing therapy for … antitachycardia pacing in implanted cardioverter defibrillators

Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: antitachycardia pacing therapy during charging

W Schoels, D Steinhaus, WB Johnson, G O'Hara… - Heart Rhythm, 2007 - Elsevier
… Previous studies in implantable cardioverter-defibrillator (ICD) patients demonstrated the
efficacy and safety of antitachycardia pacing (ATP) for rapid ventricular tachycardias (VT). To …

Antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with prophylactic cardioverterdefibrillator therapy

W Grimm, E Plachta, B Maisch - Pacing and clinical …, 2006 - Wiley Online Library
… Aims: Antitachycardia pacing (ATP) has not routinely been used in patients who received
implantable cardioverter defibrillators (ICDs) for primary prevention of sudden death. This study …

Clinical experience with antitachycardia pacing and improved detection algorithms in a new implantable cardioverter-defibrillator

D Wietholt, M Block, F Isbruch, D Böcker… - Journal of the American …, 1993 - Elsevier
antitachycardia pacing modes and detection algorithms in patients with a new third-generation
implantable cardioverter-defibrillator… studies, in 28 patients antitachycardia pacing was …

Antitachycardia pacing to terminate ventricular tachyarrhythmia: new insights into how to reduce painful implantable cardioverter defibrillator shocks

JO Schwab - Europace, 2012 - academic.oup.com
… (FVT) by the delivery of antitachycardia pacing (ATP) through the right ventricular
implantable cardioverter defibrillator (ICD) lead was first … Properties of antitachycardia pacing

Antitachycardia pacing in patients with implantable cardioverter defibrillators: how many attempts are useful?

R Fries, A Heisel, G Kalweit, J Jung… - Pacing and clinical …, 1997 - Wiley Online Library
… The purpose of this study was to determine the termination and acceleration rates for 1 to
6 attempts of antitachycardia pacing (ATP) delivered by ICD in order to terminate sponta…

Role of antitachycardia pacing in patients with third generation cardioverter defibrillators

HJ TRAPPE, H Klein, B Kielblock - Pacing and Clinical …, 1994 - Wiley Online Library
… First and second generation ICD devices had only cardioversion or … have antitachycardia
pacing modes, cardioversion and defibriiiation back-up as well as antibradycardia pacing.^-** …